To Cancel the Stay Zones
+ [ZONE NUMBER] +
If an area programmed as a STAY zone will no longer be entered during STAY arm, then
the zone should be removed from the stay profile. This will allow the system to protect
that area during a stay arm cycle.
1. Hold down the [3] key until the keypad buzzer sounds. The AWAY indicator will flash
to show that the panel is in the Stay zone programming mode.
2. Press the [NUMBER] corresponding to the STAY zone you wish to cancel.
3. The relevant zone indicator will turn off.
4. Repeat step 2 until all stay zones are selected.
5. Press the [#] key to exit the Stay zone programming mode.
NOTE:
The system will automatically exit this mode after 60 seconds.
The 806 has two stay profiles that could be used if required
Buzz Zones
Buzz zones are used when Stay arming. When triggered, buzz zones will cause the
keypad buzzer to sound for a period of 30 seconds during which time a valid user code
must be entered. If a valid user code is not entered during this period, the system will
register an alarm condition. It is advisable to program Buzz zones if you are likely to
accidentally trigger these zones or if you have pets.
This feature helps prevent unnecessary false alarms.
NOTE:
Instant zones, such as panic zones, cannot be selected.
To Program Buzz Zones
+ [ZONE NUMBER] +
1. Hold down the [4] key until the keypad buzzer sounds. The AWAY indicator will flash
to show that the panel is armed in the Buzz zone programming mode.
9. Press the [NUMBER] corresponding to the zone you wish to be a Buzz zone.
10. The lit zone indicator will show the relevant Buzz zone. (Stay zones will be shown
by flashing indicators. See Pg. 18. A Stay zone cannot be selected as a Buzz zone;
the Stay status must be cleared first).
11. Repeat steps 2 until all the required Buzz zones are programmed.
12. Press the [#] key to exit the buzz programming mode.