Pulse Count is the amount of times the detector needs to be triggered within a 20
second period before an alarm condition is sent.
When the 862-01-CX-702RSC detector is in Normal Operation it will only send an alarm
after a wait period of 120 seconds from the last alarm condition.
PIR Lens
Tamper Switch
Walk Test Jumper
On Enables Walk Test (LED is
enabled, Pulse Count set to 1)
Off Normal Operation
Pulse Count Jumper
On Sets Pulse Count to 2
Off Sets Pulse Count to 4
PIR LED
Enabled in Walk Test Mode,
Disabled in Normal Mode
Supervision Jumper
J1 On 90 mins
J1 Off 12 hrs
IDS Wireless
Transmitter
Power Connector
Connect the battery
holder lead here.
Detector Inputs
Tamper & PIR inputs
come from the
detector.