EasyManua.ls Logo

IDTECH VersaKey - Appendix A MagStripe Reader Default Settings

Default Icon
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A MagStripe Reader Default Settings
The Reader is shipped from the factory with the following magnetic stripe default
settings.
Default Functional Settings
Magnetic Stripe Data Output Format
Magnetic Track Basic Data Output Format
Track 1: <SS1><T
1
Data><ES><TS>
Track 2: <SS2><T
2
Data><ES><TS>
Track 3: <SS3><T
3
Data><ES><Terminator>
Where: SS1(start sentinel track 1) = %
SS2(start sentinel track 2) = ;
SS3(start sentinel track 3) = ; for ISO, % for AAMVA
ES(end sentinel all tracks) = ?
<TS> = <ENTER> key or CR
Terminator = <ENTER> key or CR
Start or End Sentinel: Characters in encoding format which come before the first
data character (start) and after the last data character (end), indicating the
beginning and end, respectively, of data.
Track Separator: A designated character that separates data tracks.
Terminator: A designated character that comes at the end of the last track of data
in order to separate card reads.
LRC: Check character, following end sentinel. (The reader will verify it when
decoding, but this will not be sent as part of the data.)
Function Default Value
Terminal Type PC/AT (Auto Selects)
Beep Volume High
Character Delay 2 ms
Track Selection Any Track
Data Output Format ID TECH Format
Track Separator See Section 7.3
MSR Reading Enable
Decoding Method Decoding in Both Directions
Terminator ID ENTER (Keyboard)