FAULT DIAGNOSIS
WHY DOES IT HAPPEN?
PILOT LAMP DOES NOT GLOW.
q Check if the machine is ON.
q Check for loose connections in plug/socket.
q Check for blown fuse
WATER DOES NOT ENTER MACHINE/DETERGENT NOT
BEING FLUSHED INTO DRUM.
q Check water supply
q Porthole door not firmly closed
q Water tap not turned on
q Bent inlet hose
q Sieve on inlet valve clogged
SUDS ESCAPING FROM DETERGENT DISPENSER TRAY.
q Detergent used is not washing machine detergent
q Excessive detergent used
q Drain Line is blocked
WATER LEAKAGE FROM THE MACHINE.
q Inlet/Outlet hose connection loose
q Fluff Filter not screwed on properly
q Inlet hose leaking
MACHINE DOES NOT DRAIN.
q Fluff Filter clogged
q Outlet hose end above 1 mtr. from floor level
MACHINE VIBRATES STRONGLY DURING SPINNING.
q Machine not levelled properly
q Clothes not loaded as instructed
q Water not drained completely
MACHINE DOES NOT START.
q Check position of programme selector knob
q Check water supply
q Porthole door not closed properly
q Indicator lamp not glowing
MACHINE DOES NOT SPIN.
q Check if the Spin Cancel Button is pressed.
MOTOR NOISE
q It is normal for noises to be heard while motor is running. However
wash load, belt tension and motor mounting bolt should be
checked for specified limits.
PUMP NOISE
q It is normal for noises to be heard from the pump during the start-up
and final stage of draining. However check for fluff filter clogging.