IO-Link Master with Modbus TCP Interface DataLine 4 Ports IP 65 / IP 66 / IP 67
>
9.3.9 Read device information
34451
The user can read device information using the FC43.
The AL1340 supports the following data records ("Read Device ID code"):
Basic Device Identification (0x01): contained data objects: → Modbus TCP specification
Regular Device Identification (0x02): contained data objects: → Modbus TCP specification
Specific Device Identification (0x04): contained data objects:
Object name / description
IO-Link Master DL MOD 4P IP67
>
9.3.10 Control IO-Link master
34458
The user can control the IO-Link master using the following acyclic commands:
"Reboot": →Command 0x40 – Reboot (→ S. 110)
"Factory Reset": →Command 0x50 – Factory Reset (→ S. 111)
The commands use the process mechanisms of the acyclic command channel (→Use acyclic
services (→ S. 75)).
>
9.3.11 Configure IO-Link devices
33881
The IO-Link master supports the configuration of the connected IO-Link devices from the Modbus TCP
projection software. The parameters of an IO-Link device are set via IO-Link index and subindex. The
number of the configurable parameters depends on the connected IO-Link device.
Available parameters of the IO-Link devices: → IO Device Description (IODD) of the IO-Link
device
The user can read and write IO-Link index and subindex using the following methods:
Acyclic communication: → Use acyclic services (→ S. 75)