NAVAIR
17-2OAX-737
4.7.25
Set
the
TI
LOC
DDM
switch
to
150
Hz.
4.7.26 Verify
that
the
signal
generator
calibrator
indicates
between
38.4%
and
41.6%
AM
modulation,
and
record
the
reading.
4.7.27 Verify
that
the
TI
meter
indicates
within
±1.6%
of
the
recorded
value
in
step
4.7.26.
4.7.28
Set
the TI
LOC
DDM
switch
to
0,
and
the
FREQUENCY
MHz
switches
to
118.000.
4.7.29
Activate
the
signal
generator
calibrator
50
HzHPFILTER,
and
the
15
kHz
LP
FILTER.
4.7.30 Verify
that
the
signal
generator
calibrator
indicates
between
28.8%
and
3
1.2% AM
modulation.
4.7.31
If
the
TI is a
NAV—750B,
proceedwithstep
4.7.32.
Otherwise,
if
the
TI
is
not
a
NAV—750B,
skip
to
step
4.7.41.
4.7.32
Set
the TI
controls
as
follows:
FREQUENCY
MHz
switches
to
075.000
MASTER
MOD
control
to
CAL
(UNCAL
lamp
off)
Meter
function
and
toneSelector
switch
to
400
Hz
1020
Hz
indent
tone
MOD
control
to
CAL
(UNCAL
lamp
off)
Output
attenuator
control
to
—20
dBm
4.7.33
Press
the
signal
generator
calibratorINSTR
PRESET
key
(Blue
key,
AUTOMATIC
OPERATION
key),
and
ensure
that
the
signal
generator
calibrator
is in
the
FREQ
measurement
mode
and
tunes
to
the
TI
FREQUENCY
MHz
switches
setting.
Set the
signal
generator
calibrator
for
AMmodulation
measurements
with
the
DETECTOR
set
to
PEAK
±12.
Activate
the
signal
generator
calibrator
50
Hz
HP
FILTER,
and
the
15
kHz
LP
FILTER.
4.7.34 Verify
that
the
signal
generator
calibrator
indicates
between
92.
15%
and
97.85%
AM modulation,
andrecord
the
reading.
4.7.35 Verify
that
the
TI
meter
indicates
within
±3%
of
the
recorded
value
in
step
4.7.34.
4.7.36
Set
the TI
meter
function
and
tone selector
switch
to
1300
Hz.
4.7.37 Verify
that
the
signal
generator
calibrator
indicates
between
92.
15%
and
97.85%
AM
modulation.
4.7.38
Set the
TI
meter
function
and
tone selector
switch
to
3000
Hz.
4.7.39
Activate
the
signal
generator
calibrator
300
Hz HPFILTER,
and
the
>20
kHz
LP
FILTER.
4.7.40 Verify
that
the
signal
generator
calibrator
indicates
between
92.
15%
and
97.85%
AM
modulation.
4.7.41
Disconnect
the
signal
generator