4 AA-2194922-3
All dimensions are in inches (cm).
Only some models are available in Canada.
* Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for installation of the junction
box on the wall at the back of the cooktop.
Cooktop Dimensions
Cooktop Cutout Dimensions
Figure 1
IMPORTANT INSTALLATION INFORMATION
All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz,
AC only electrical supply with ground.
Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
A
F
B
C
D
E
30" Min. *
(76.2 cm)
MODEL
A.
LENGTH
B.
WIDTH
C. DEPTH
CUTOUT DIMENSIONS
F. DEPTH
BELOW
COOKTOP*
D. LENGTH E. WIDTH
MIN. MAX. MIN. MAX.
30"
30"
(76.2 cm)
21
3
/
8
"
(54.4 cm)
2
5
/
8
"
(6.7 cm)
28½"
(72.4 cm)
29
7
/
8
"
(75.9 cm)
19
5
/
8
"
(49.9 cm)
20½"
(52.1 cm)
5"
(12.7 cm)
To eliminate the risk of burns or re by reaching over heated surfaces, cabinet
storage space located above the cooktop should be avoided. If cabinet storage is provided,
risk can be reduced by installing a range hood that projects horizontally a minimum of
5" (12.7 cm) beyond the bottom of the cabinets.
CAUTION!