9
Figure 7
4-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
White
Wires
Junction
Box
Cable from appliance
Ground
Wire
(Bare or
Green Wire)
Ground
Wire
Black
Wires
Red
Wires
U.L.-Listed Conduit
Connector (or CSA listed)
Your appliance has a 4-wire cable to be
connected to a 4-wire grounded junction box
(see gure 7):
1. Disconnect the power supply.
2. In the junction box:
Connect appliance and power supply cable wires
as shown in Figure 7.
Cooktop Installation
1. Visually inspect the cooktop for damage. Also
make sure all cooktop screws are tight (see
Figure 8).
2. Set the cooktop into the countertop cutout.
Screws
Figure 8
Figure 9
8 Built-in
Springs
2 Retainer
Brackets
Position brackets
on unit cutout
center line (CL)
The retainer brackets MUST be installed, to
meet local codes or, in their absence, with
the National Electrical Code ANSI/NFPA No.
70—latest edition, or with CSA Standard
C22.1, Canadian Electrical Code, Part 1 (see
Figure 11).
During the installation with wide cutout, make sure
the cooktop is centered. A and B gap should have
the same dimensions. The elongated holes on the
bottoms of the installation brackets are made to t
every cutout.
Cooktop
Retainer Brackets
Must Be Installed At
Least 1/8" (0.3 cm)
BELOW Countertop
Built in
Spring
Countertop
Retainer Bracket
Figure 11
Figure 10
Do not remove the built in springs on the
edges of the cooktop. These springs center
the cooktop in the space provided. The
cooktop must be centered to prevent excess
heat buildup that may result in heat damage
or re (see Figure 9).
WARNING!
Screw 1
Screw 2