ESPRIT INBUILT MANUAL 2014
Quality & Value In Gas Log Fires
3
ILLUSION GAS LOG HEATERS - MODELS EGL62NG, EGL69NG, EGL62LP AND EGL69LP
Electrical components conform to AS 3100 240V 50hz 60 watts
AGA APPROVAL NUMBER- 6286
Model EGL62NG EGL69NG EGL62LP EGL69LP
Injector Size 3.0 3.8 1.8 1.8
Manifold Pressure kPa 0.95 0.85 1.4 2.25
Gas Consumption Mj/h 32 40 29 37
Gas Type NAT NAT LP LP
Average Efciency % 76.9 75.9 78.6 77.8
Max kW Output 7.11 8.38 6.3 7.91
Manufactured by
ILLUSION Australia Pty. Ltd.
145 Sth Gippsland Hwy.
Dandenong Sth.
3175
Victoria Australia
!
DO NOT
DO NOT
DO NOT
DO NOT
OPERATE THIS APPLIANCE BEFORE READING THE
INSTRUCTION BOOKLET
PLACE ARTICLES ON OR AGAINST THIS
APPLIANCE
STORE CHEMICALS OR FLAMMABLE MATERIALS
OR SPRAY AEROSOLS NEAR THIS APPLIANCE
OPERATE WITH PANELS, COVERS OR GUARDS
REMOVED FROM THIS APPLIANCE
THE GUARD IS FITTED TO THIS
APPLIANCE TO REDUCE THE RISK
OF FIRE OR INJURY FROM BURNS
AND NO PART OF IT SHOULD BE
PERMANENTLY REMOVED.
FOR THE PROTECTION OF YOUNG
CHILDREN OR THE INFIRM,
A SECONDARY GUARD IS REQUIRED.
PLEASE NOTE A S P E R A G A 1 0 3 A P R I M A R Y S A F E T Y G U A R D I S S U P P L I E D
AND MUST BE FITTED WHEN THE HEATER IS OPERATING.
Main Gas Connection
The connection is made using gas pipes with Rp1/2 ISO 7 threading. Torque: 25Nm
If, alternatively, anges are used, rst screw the pipes on to the anges and then the
anges to the valve. Recommended torque for the ange xing screws: 3Nm.
Connection to the pilot burner
Pipes with Ø 4mm, Ø 6mm or Ø 1/4 can be used. Use a nut and olive of appropriate dimensions.
Tighten the nut to 7 Nm torque.
Electrical Connections
Use the special connectors for connection to the thermopile and to the thermostat.
Make the connections in accordance with the plan below and in accordance with the rules for the appliance. The electrical safety cut
off devices (for example, the ame failure device, limit thermostat and the like) must cut off the power supply to the thermoelectric
circuit of the gas valve.
Caution: After making the connections, check gas tightness.
LABELLING