EasyManua.ls Logo

Illusion MATRIX GFX-S - User Manual

Default Icon
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MATRIX MANUAL 2014
Your new ILLusion Gas Log Fire was designed and manufactured in Australia.
It is tted with the nest, most detailed gaslogs available, cast from real “Australian” box
timber and carefully hand painted by craftsmen. Features include an enormous ceramic glass
viewing area, and fascia options to suit almost any home.
Thes appliances have been tested and approved in accordance with Australian Standards
for installation and operation as described in this manual and have been
certied by SAI GLOBAL
WARNING: DO NOT MODIFY THIS APPLIANCE
All Illusion Gas Log Appliances MUST be installed and serviced by an authorised person.
OWNERS INSTRUCTION & INSTALLATION MANUAL. PLEASE KEEP FOR FUTURE REFERENCE
HEAD OFFICE 145 STH GIPPSLAND HWY. DANDENONG VICTORIA AUSTRALIA 3175
PH: 03 9793 7520 Email sales@illusionres.com.au
www.illusionres.com.au
Model MATRIX GFX-L, GFX-M, GFX-S Gas Log Fires
Question and Answer IconNeed help?

Do you have a question about the Illusion MATRIX GFX-S and is the answer not in the manual?

Summary

Model Overview and Specifications

Model Identification and Features

Introduces Illusion Matrix Gas Log Fire models GFX-L, GFX-M, GFX-S, highlighting Australian manufacturing.

Technical Data and Certifications

Details gas types, consumption, pressure, kilowatt ratings, and safety approvals.

Appliance Operation and Controls

Lighting and Burner Ignition Procedures

Step-by-step guide for lighting the pilot and main burner, including safety cautions.

Control Identification and Functions

Identifies all control knobs, buttons, and indicators on the appliance panel.

Log Set Fitting Instructions

Detailed procedure for correctly fitting the log set to the burner for optimal performance.

Installation Requirements and Methods

Pre-Installation Safety and Regulations

Crucial safety information, installation regulations, and preparation steps before installation.

Installation Procedure and Options Overview

Step-by-step installation process, clearances, flue system, and positioning advice.

Installation Options 1-4

Illustrates flue installation options, including fabricated enclosures and existing chimneys.

Fascia and Trim Fitting Instructions

Specific instructions for attaching both floor mount and wall mount fascia types.

Maintenance, Troubleshooting, and Parts

Pressure Testing and Gas Valve Checks

Procedure for pressure testing the gas valve for correct operation.

Routine Maintenance and Log Care

Annual service guidelines, cleaning instructions, and precautions for replacing logs.

Wiring Diagram and Parts Identification

Electrical wiring diagram and an exploded view of appliance parts for reference.

Troubleshooting Common Issues

Addresses common problems, their causes, and solutions for the gas log fire.

Advanced Features and Controls

Thermostatically Controlled Fan

Explains the automatic operation of the fan based on temperature and remote control.

Optional Remote Control Operation

Details the functionality, setup, and battery replacement for the optional remote control.

Contact Information

Illusion Gas Log Fires Contact Details

Provides contact information for Illusion Australia Pty Ltd, including addresses and phone numbers.

Overview

The Illusion Matrix series of Gas Log Fires, including models GFX-L, GFX-M, and GFX-S, are Australian-made appliances designed to provide continuous warmth with the aesthetic appeal of an open fire. These units are intended for installation in suitably constructed wall or fireplace facades and must be installed by an authorized person in accordance with Australian Standard AS/NZS5601.

Function Description:

The Illusion Matrix Gas Log Fires are gas-fueled heating appliances that simulate the appearance of a traditional wood-burning fireplace. They feature highly detailed gas logs, cast from real Australian box timber and hand-painted, which contribute to a realistic flame effect. The appliance incorporates a full ceramic glass front for safety and an enormous viewing area to enhance the visual experience. These units are designed to operate with luminous flames, though slight carbon deposition may occur. They are equipped with a thermostatic fan for efficient heat distribution and can be controlled manually or via an optional radio frequency remote controller.

Important Technical Specifications:

  • Gas Type: Natural Gas (NAT) for all models (GFX-L/NG, GFX-M/NG, GFX-S/NG).
  • Nominal Gas Consumption:
    • GFX-L/NG: 40.0 Mj/h
    • GFX-M/NG: 34.0 Mj/h
    • GFX-S/NG: 28.0 Mj/h
  • Manifold Pressure:
    • GFX-L/NG: 0.82 kPa
    • GFX-M/NG: 0.78 kPa
    • GFX-S/NG: 0.90 kPa
  • Turndown Pressure:
    • GFX-L/NG: 0.34 kPa
    • GFX-M/NG: 0.32 kPa
    • GFX-S/NG: 0.50 kPa
  • Injector Size:
    • GFX-L/NG: 3.00 mm
    • GFX-M/NG: 2.7 mm
    • GFX-S/NG: 2.5 mm
  • Kilowatt Rating (Vertical Flue) On High:
    • GFX-L/NG: 8.41 kW
    • GFX-M/NG: 7.14 kW
    • GFX-S/NG: 5.64 kW
  • Kilowatt Rating (Horizontal Flue) On High:
    • GFX-L/NG: 7.87 kW
    • GFX-M/NG: 6.86 kW
    • GFX-S/NG: 5.71 kW
  • Electrical Components: Conform to AS 3100, 240V 50Hz 60 watts.
  • Gas Connection: Rp1/2 ISO 7 threading, torque 25Nm. A suitable Certified flexible stainless steel pipe is recommended, with a Certified shutoff valve fitted between the incoming gas line and the appliance.
  • Flue System:
    • Minimum diameter of active flue for all models: 127mm.
    • Stainless steel active flue must be used for rear flue models.
    • Galvanised steel may be used for vertical flue models.
    • Minimum overall height of flue system (vertical flue exit models): 3.6 meters.
    • Minimum horizontal flue: 300mm (not including gas flue cowl assembly).
    • Only the certified gas flue cowl assembly as tested with the appliance may be used.
  • Dimensions (External, in millimetres):
    • GFX-S: A=945, B1=875, B2=795, C=740, D=520, E=530, F=80, G=650, H=285, I=903.
    • GFX-M: A=1045, B1=960, B2=880, C=830, D=520, E=612, F=80, G=750, H=285, I=1003.
    • GFX-L: A=1140, B1=1045, B2=972, C=920, D=520, E=701, F=80, G=850, H=285, I=1099.
  • Suggested Wall Cut Out Sizes (Minimum):
    • GFX-S: Height (Y) 780mm, Width (X) 920mm, Depth (Z) 600mm.
    • GFX-M: Height (Y) 865mm, Width (X) 1020mm, Depth (Z) 600mm.
    • GFX-L: Height (Y) 950mm, Width (X) 1120mm, Depth (Z) 600mm.
    • Note: Allow min. 150mm up from floor when fitting standard window fascia and extra if skirting is fitted.

Usage Features:

  • Lighting Instructions:
    • Pilot Flame Ignition: Depress and turn the control knob to "PILOT," then press the red igniter button while keeping the knob fully depressed for a few seconds. Release slowly and ensure the pilot flame stays lit.
    • Main Burner Ignition: Turn the HI-LO control knob to HI, then depress and turn the control knob to "ON." Gas passage to the main burner opens when the automatic solenoid valve is energized.
    • Pilot Position: To keep the main burner closed and the pilot flame lit, depress and turn the control knob to "PILOT."
    • Turning Off: Depress and turn the control knob to the "OFF" position.
    • A restart interlock device prevents ignition until flame failure has stopped gas flow.
  • Control Identification: Features include a gas off/pilot on/main gas on control, HI-LO flame control, push-button piezo igniter, fan control switch (Boost, Medium, Off), and a remote control receiver.
  • Primary Guard: The appliance is supplied with a primary guard that must be fitted during operation to prevent severe burns from contact with the extremely hot glass front. A secondary fire screen may be appropriate for households with small children or the infirm. The primary guard fits over the door frame without screws.
  • Thermostatically Controlled Fan: The fan automatically turns on 10-15 minutes after the heater reaches a predetermined temperature and shuts off 10-15 minutes after the heater cools down. Fan speed can be set to Low, High, or Boost.
  • Optional Radio Frequency Remote Control: Allows operation within approximately 6m of the appliance. It is a programmable unit that can be wall-mounted and uses 2 'AAA' batteries for the hand unit and 4 'AA' batteries for the receiver. The remote allows switching on/off, activating the thermostat mode, and displaying room temperature. The fan will only start if the fan speed is set to LOW, HIGH, or BOOST.
  • Paint Curing: Initial firing may produce smoke and odor as the heat-resistant paint cures. It is advisable to run the unit on high without the fan for approximately 3-4 hours with windows and doors open during this period.
  • Abnormal Operation: If flames appear excessively large or soot occurs, gas smell is detected, flame pattern is inconsistent, or flue products are smelled, turn off the appliance and contact the supplier or installer immediately. If gas is smelled, turn off the main gas supply and call appropriate authority from outside the building.

Maintenance Features:

  • Annual Service: Must be performed by an authorized person.
  • Cleaning:
    • Clean the burner and control compartment of lint and house dust at least once a year using a soft clean brush and vacuum.
    • Clean the logs with a soft clean brush as they are fragile.
    • When cold, wipe surfaces with a damp cloth; avoid abrasive cleaners.
  • Flame Check: Periodically check that flames are steady, not lifting off burner ports, and logs are free of soot. If issues arise, contact an authorized gas fitter or local dealer.
  • Appliance and Flue System Inspection: Must be inspected by an authorized person before use and at least annually.
  • Clearance: Keep the area near the appliance clear of combustible materials, gasoline, aerosols, and other flammable vapors and liquids.
  • Replacing Logs: The unit should never be used if logs, coals, or rocks are broken. Always turn off the gas valve and allow the unit to cool before handling. Replacement parts must be fitted by an authorized person. Improper positioning of logs can cause soot buildup, carbon monoxide, and affect appliance performance, potentially voiding the warranty.
  • Troubleshooting: The manual provides solutions for common issues such as pilot flame going out, main burner flame going out while pilot stays on, heater turning off after 30 minutes, sooting on logs, fan rattling, strong odor/smoke on first use, and unit not lighting beyond pilot flame. For persistent issues, contact Illusion Australia directly.

Safety Information:

  • Installation must be by authorized personnel according to regulations, municipal building codes, electrical wiring regulations, and AS/NZS 5601 'GAS INSTALLATIONS'.
  • Do not modify or adjust the appliance.
  • Do not place articles on or against the appliance.
  • Do not store chemicals or flammable materials near the appliance.
  • Do not spray aerosols in the vicinity of the appliance while it is in operation.
  • Never attempt to light the appliance if you smell gas.
  • Keep clothing, children, and furniture away from the hot appliance.
  • The appliance is not designed to burn solid fuels; never use paper, wood, or other fuel.
  • The flue system must terminate outside the building, never within the roof cavity.
  • Annual service by an authorized person is required for trouble-free operation.

Illusion MATRIX GFX-S Specifications

General IconGeneral
BrandIllusion
ModelMATRIX GFX-S
CategoryIndoor Fireplace
LanguageEnglish