Display | LCD |
---|---|
Sampling Rate | 1000 Hz |
Power Supply | AC adapter |
Interface | RS-232C |
Operating Temperature | 0°C to 40°C |
Units | kgf |
Functions | Peak hold |
Storage Temperature | -10°C to 50°C |
Warns about sample/fixture breakage and the need for protective gear.
Warns against exceeding capacity; damage occurs at 110% and destruction at 200%.
Specifies the operational temperature range for optimal accuracy.
Details required screw size and maximum insertion depth for gauge mounting.
Advises measuring forces strictly in line with the shaft to prevent damage.
Instructs to hand-tighten attachments to avoid damage.
Emphasizes powering down the unit before connecting/disconnecting cables.
States that disassembling the gauge will void the warranty.
Specifies using only Imada-approved chargers for the unit.
Describes the optional handle designed for heavy load measurements.
Details software for capturing, analyzing, and charting measurement data.
Lists available cables for data transmission and device connectivity.
Explains how to change the measurement units (ozf, lbf, kgf, N).
Details the procedure to invert the display orientation for usability.
Describes RS-232C interface for remote control and data transmission.
Reiterates not using tools for attachments to prevent damage.
Explains how to switch between real-time and peak measurement modes.
Describes how to tare the gauge, zeroing weight and clearing peak.
Advises on applying force correctly in line with the measuring shaft.
Guides on connecting to a PC and transmitting data using SW-1 or other software.
Details programming setpoints for GO/NG testing and indicator behavior.
Explains how to select between Destructive (FA) and Non-destructive (SL) testing modes.