15
• Remove the dust collection compartment cover (12A), turning it anticlockwise [Fig. E2].
• Remove the ltering system (12B+12C+12D+12E) [FIG E3]
• Empty the dust collection compartment (12F) [FIG. E4].
• When necessary, rinse the dust collection compartment (12F) and dry it completely.
• Ret the ltering system (12B+12C+12D+12E) in the dust collection compartment (12F) [FIG E3].
• Ret the dust collection compartment cover (12A), turning it clockwise [Fig. E2].
• Insert the dust collection system (12) onto the appliance, inserting the lower part in the correct seat
[g. E1].
• Press the upper part of the dust collection system until it clicks, which indicates that is it locked
correctly (12).
NOTE:
A safety device means that the dust collection compartment (8A) on the
appliance cannot be closed if the filtering system (8B+8C) is not present or fitted
incorrectly.
Cleaning the filtering system (12B+12C+12D+12E)
• Press the two release buttons (14) for the dust collection compartment and detach the dust collection
system (12) from the appliance [Fig. E1].
• Remove the dust collection compartment cover (12A), turning it anticlockwise [Fig. E2].
• Remove the ltering system (12B+12C+12D+12E) [FIG E3].
• Remove the HEPA lter (12B), pulling it upwards using the correct ring.
• Remove the plastic lter dust separator (12E) from the plastic lter (12D), turning it clockwise.
• Remove the sponge lter (12C) from the HEPA lter (12B).
• Clean the HEPA lter (12B) using a soft brush to prevent any damage.
• Wash the sponge lter (12C) with cold water and leave it to dry completely.
• Wash the plastic lter (12D) with cold water, taking care not to damage it and leave it to dry
completely.
WARNING! Let the filters dry completely after washing them
for at least 24 hours before reassembly.
WARNING! Make sure all cleaned parts are completely dry
before reusing the appliance.
• Ret the plastic lter dust separator (12E) on the plastic lter (12D), turning it clockwise.
• Insert the sponge lter (12C) in the HEPA lter (12B).
• Insert the HEPA lter (12B) in the plastic lter (12D).
• Insert the dust collection compartment cover (12A), and fasten it turning it clockwise [Fig. E2]
• Insert the ltering system (12) in the main body, it clicks into place when it is fastened correctly.
• Press the grille release button (10A) and remove the grille (10).
• Remove the HEPA lter (11).
• Clean the lter (11) and the lter protection grille (10) by shaking and brushing the dust off carefully.
Use a soft brush to prevent any damage.
• If the lter (11) is clogged with dust, carefully wash it with water. Take care not to damage the lter
and leave it to dry completely.
• Ret the grille (10), when the grille release button (10A) clicks into place it is fastened correctly.
If the suction power of the vacuum cleaner does not increase after cleaning the dust collection
compartment (12F), and the filtering system (12B+12C+12D+12E), replace the filters 11, 12B and 12C.