IMEX ROTATING LASERS
OPERATING MANUAL
77R 88R and 88G

Questions and Answers

  • N
    Nichole WatsonAug 8, 2025
    What to do if the imex 88R is out of level and the battery light is on?
    • J
      James KiddAug 8, 2025
      If your imex Laser Level displays an out-of-level alert along with the battery light, and the instrument isn't working correctly, it might be due to harsh environmental conditions or direct sunlight. Move the unit to a shaded area where the temperature is below 50ºC.
  • T
    Tonya WilsonAug 14, 2025
    Why is my imex 88R Laser Level receiver not working properly?
    • C
      castilloamberAug 14, 2025
      If the receiver for your imex Laser Level isn't functioning correctly, here are a few things to check: * First, ensure the receiver batteries are good and replace them if needed. * Second, verify that the receiver is within the working range (250m radius) of the unit. * Finally, make sure the laser windows are clean, free of dust, and not obstructed.
  • A
    Anthony LoweryAug 20, 2025
    How to fix imex 88R Laser Level remote control that is not working?
    • B
      brownchristopherAug 20, 2025
      If the remote control for your imex Laser Level isn't working, try the following: * Check and replace the remote control batteries. * Ensure the remote is within the working range of the unit (20m outdoors, 30m indoors). * Verify that the instrument is turned on.
  • A
    acoxAug 27, 2025
    What to do if the imex 88R Laser Level shows a low battery light and won't operate?
    • C
      Curtis DanielsAug 27, 2025
      If your imex Laser Level shows a flashing low battery light and won't power on, try these steps: 1. Recharge the batteries. 2. If the batteries are fully charged but the unit still won’t operate, open the battery terminals to check if they are clean and have the correct polarity. 3. If the batteries have been overcharged frequently, they may need replacing.
  • M
    mark50Sep 1, 2025
    How to resolve an out of level alert on my imex 88R?
    • R
      Ronald JohnsonSep 1, 2025
      If your imex Laser Level displays an out-of-level alert and won’t self-level, ensure the instrument is within 5º of level before switching it on. Also, check that the manual level switch is not activated and that the unit hasn’t been bumped or moved.

Summary

2. Basic Operation

2.1 Standard Set-up Leveling

Step-by-step guide for setting up and leveling the laser instrument on a tripod.

2.3 Receiver Set-up

Instructions for setting up the laser receiver on a staff or grade rod.

3. Manual Grade Operation

3.1 Manual Mode

How to activate and use manual grade mode for setting slopes.

3.2 Setting a Slope

Method and steps to set a specific percentage slope using the instrument.

3.3 Dual Grade Sloping - (88 R & 88 G only)

Guide for setting simultaneous slopes on X and Y axes for specific models.

4. Scan Mode Operation (88 R & 88 G only)

5. Vertical Function - 88 R & 88 G only

7. Checking Accuracy

8. Trouble Shooting

imex 88R Specifications

General IconGeneral
Power Source4 x AA batteries
Water/Dust ResistanceIP54
Laser Diode635 nm
Power Supply4 x AA batteries
Operating TimeUp to 20 hours
Protection RatingIP54
Laser ClassClass 2
Rotation Speed600 rpm