11. TECHNICAL CHARACTERISTICS
• Dimensions (LxHxD): ....................................................................................................................................128 x 98 x 36 (mm)
• Power Supply: ........................................................................................................................................24V nominal (12V...24V)
• Maximum input:................................................................................................................................max 10 mA (max 250 mW)
• Functioning room temperature: ....................................................................................................................................0 - +50°C
• Warehouse temperature: ..............................................................................................................................................-10 - +60°C
• Protection rating according to EN 60730: .................................................................................................................................. II
• Protection rating according to EN 60529: ............................................................................................................................ IP 20
• Power supply electrical features: ............................................................................................................. polarised bipolar cable
• Communication electrical features: ....................................................................................................... polarised bipolar cable
• Connection cable max. length: ............................................50 m (with cable 2x0.75mm
2
) (0.5 ÷mm
2
min - 1.5 mm
2
max)
• Precision indication room temp.: ................................................................................................................... +/- 0.5°C at 25°C*
• Humidity probe accuracy: ............................................................................................................................................... +/- 10%*
• Clock indication diversion ........................................................................................................................... +/- 15 minutes/year
* = the indications of the room temperature and humidity can be aected by the point of installation of the Zone Remote
Panel (e.g. hot wall, cold wall, height from the ground, etc.)
11.1 Product sheet.
In compliance with Regulation 811/2013, the class of the temperature control device is:
Class
Contribution to room central heating
seasonal energy eciency
Description
V
+3% Zone Remote Panel
VI +4%
Zone Remote Panel combined with external probe