24
INSTALLERUSERMAINTENANCE TECHNICIAN
2.4 SYSTEM USE.
Before ignition, make sure the system is full of
water, checking that the pressure gauge needle
(6) points to a value between 1 and 1.2 bar and
make sure that the chiller circuit has been lled
as described in the condensing unit instructions
booklet.
- Open the gas cock upstream from the indoor
unit.
- Press the button (1) until the display switches
on. e system now goes back to the state prior
to switch-o.
(During ignition, the display shows in se-
quence: display segments all lit, parameter A11,
parameter A13).
- If the indoor unit is in stand-by, press the
button (1) again to activate it. If this is not the
case, go to the next point.
- en press the button (1) in sequence and set
the system to summer ( ), winter ( ) or
heating/air conditioning ( ) position.
e system, based on the settings you made, au-
tomatically handles which energy source to use,
choosing the most ecient among those available
to meet system requirements (Fig. 36). For example
the same request (i.e. domestic hot water request)
can be satised by the use of condensing unit,
shown by its symbol ( ), or by the heat gene-
rator ( ). As an example of operation, below is
represented for practicality the condensing unit
operation mode.
Summer ( ): in this mode, the system only
works to produce domestic hot water, the
temperature is set using the buttons (4) and
the corresponding temperature is shown on
the display by the indicator (14).
Summer and DHW heating in
progress mode
32
• Winter ( ): in this mode, the system works
both to product domestic how water and room
central heating. e temperature of the DHW
is always regulated via buttons (4), the central
heating temperature is regulated via buttons
(5) and the relative temperature is shown on
the display by the indicator (14).
Winter and room central heating in
progress mode
33
Heating/air conditioning ( ): in this mode,
the system works both to produce DHW and to
cool the room. e temperature of the DHW
is always regulated via buttons (4), the cooling
temperature is regulated via buttons (5) and the
relative temperature is shown on the display by
the indicator (14).
Heating/Air conditioning and room
cooling in progress mode
34
From here on, the system works automatically.
If there are no requests (room central heating,
DHW production or cooling), the system goes
into the "stand-by" function. Each time the
condensing unit ignites, the display shows the
corresponding symbol (8) with the correspond-
ing power scale (10).
System's operating mode
Heat pump Heat generator
Summer
Production of Do-
mestic Hot Water
OFF ON
Winter
Production of Do-
mestic Hot Water
OFF ON
Central heating
OFF ON
or
ON OFF
Production of
DHW and central
heating
OFF ON (DHW)
or
ON (Central heating) ON (DHW)
Air conditioning
Production of Do-
mestic Hot Water
OFF ON
Room cooling ON OFF
ON (Cooling) ON (DHW)
35