15. Loosen and separate the body (15) from the heat
exchanger (19).
16. Remove the old primary valve seat (18) and
sponge (17). Discard both.
17. Remove the back cover screws (2).
18. Tap the side of the cover (22) firmly with the
handle of the screw driver to break the cover
loose from the gasket (21).