17
USING THE REFRIGERATOR AT HOME
- This model can be fed equally using 12/24V or mains power (100V - 240V AC).
- It is equipped with 2 sockets to connect the two different cables for DC respectively AC.
- The refrigerator is provided with automatic switch over from one kind of feeding to the other.
- Should both be present at the same time, the device will always set itself on mains power
priority feeding by 100V~240V AC.
ELECTRONIC CONTROL
Compressor station
Functions and features.
This is an electronic device which has the function of piloting the motor of the compressor and
carrying out all the controls and electrical protection of the system.
Its main features are as follows:
a) Protection of the battery through automatic turning off of the compressor when the feeding
voltage reaches the minimum threshold.
The compressor will start up again automatically when the voltage goes back to normal values.
Note: these values have been measured at control unit input and/or on the DC socket.
BATTERY
PROTECTION
SWITCH
POSITION
CUTOUT
12V
CUTIN
12V
CUTOUT
24V
CUTIN
24V
LOW
9.6 10.9 21.3 22.7
MED
10.1 11.4 22.3 23.7
HIGH
11.1 12.4 24.3 25.7
ENGLISH
TB45A-TB55A TB31A-TB41A-TB51A