SCM1 test procedure
MODEL TEST
PROCEDURE
ICON AND ASSOCIATED LOAD
ACTIVATION
ICON
LOAD
Length
PUMP
Key Lock
MOTOR UP +
LIGHT
Menu HEATER
Strength STEAM UNIT
2 cups
1 cup
Cappuccino
Steam
Solenoid 1 +
Solenoid 2
UP menu GRINDER
Frothy
milk
MOTOR DOWN
LOAD TEST
MODE
Scholtès Touch IFD
With the machine on stand-by (off
but with the main on/off switch set
to I), open the service door and
press and hold the 1 CUP,
STRENGTH and MENU keys at
the same time for at least 6
seconds, or until the message
“SELECT TEST” appears on the
display. After this, shut the service
door and press the CAPPUCCINO
icon: LOAD TEST MODE will
appear on the display.
To exit test mode, unplug from the
power supply.
Solenoid valve 2
(brew head) + FAN
Solenoid valve
1 (drain)