Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com
12
SPECIFICATIONS
ECOPOD-N Unit Specications
Treatment
Plant
Treatment
Capacity (GPD)
Minimum Primary
Tank Total
Volume (Gal)
Reactor Tank
Volume
(Gal)
Reactor Tank
Dilution Volume
(Gal)
Media
Size
Air
Requirements
E50N 500 500 710 590 2'x2'x4' 12 CFM
E60N 600 600 916 736 2'x2'x6' 14.4 CFM
E75N 750 750 1090 910 2'x2'x6' 18 CFM
E100N 1000 1000 1405 1165 2'x2'x8' 24 CFM
E150N 1500 1500 2100 1740 2'x2'x6' 36 CFM
MATERIALS OF CONSTRUCTION
Sux FF Reactor Tank Fiberglass
Cover Fiberglass
Media Container Polyethylene
Sux CA Reactor Tank Concrete
Cover Concrete
Media Container Polyethylene
Sux IM Reactor Tank Polypropylene
Cover Polypropylene
Media Container Polyethylene
These are standard production units. Other congurations are available upon request.
ECOPOD-N Electrical Requirements
Model Compressor Motor Full Load Amps Measured Operating Watts Electrical Requirements
E50N Delta Model 06 3.5 185 115 volt – single phase
E60N Delta Model 06 4.7 280 115 volt – single phase
E75N Delta Model 06 4.7 280 115 volt – single phase
E100N Delta Model K03 7.1 475 115 volt – single phase
E150N Delta Model K03 7.1 475 115 volt – single phase
ECOPOD-N Reactor Tank Dimensions
Treatment Plant A B C D
E50N 47” 44” 54.7” 127”
E60N 47” 44” 54.7” 127”
E75N 47” 44” 54.7” 127”
E100N 47” 44” 55” 176”
E150N 47” 44” 55” 176”