Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com
18
P (1)
ΔΔp (2)
Q (3)
kW mbar psig m
3
/h cfm
COMPRESSOR
A 50 Hz - 2900 rpm
0.2 90 1.30
B 60 Hz - 3500 rpm
0.23 80 1.16 32 19
0.4 130 1.88
EXHAUSTER
C 50 Hz - 2900 rpm
0.2 82 1.18
D 60 Hz - 3500 rpm
0.23 80 1.16 28 16
0.4 120 1.74
MAXIMUM NOISE LEVEL
Lp dB(A)
50 Hz - 2900 rpm 58
60 Hz - 3500 rpm 59
kW H m
50 Hz - 60 Hz Kg
0.2-0.23 235 6.5
0.4 235 7.1
0 10 20 30 40 50 60 70 m
3
/h
mbar
120
100
80
60
40
20
0
psig
1,5
1,0
0,5
0
0,10,2 0,30,4 Hp
mbar
120
100
80
60
40
20
0
psig
1,5
1,0
0,5
0
010 20 30 40 cfm
0,05 0,1 0,15 0,2 0,25 0,30,35 kW
A - C
B - D
mbar
120
100
80
60
40
20
0
psig
20 30 40 50 60 70 80 90 °F
10 20 30 40 50 °K
psig
1,5
1,0
0,5
0
D
A
C
D
A
B
To allow theperfect performing of the machine,ithas to be
equipped withthe INLET FILTER andthe SECURITY VALVE AT
LEAST; other accessories available on request.
(1)Installedpower.
(2)Maximum differentialpressure referredtoinstalled motor.
(3)Inletflow at max differential pressure per installed motor.
Thecharacteristics data given, refertothe handling of gas with inlet temperature of 15°C,
normaldensityof 1,23 kg/m
3
andabsolutepressure of 1013 mbar in suction in case of
performing as compressor, in discharge in case of performing as exhauster. Dimensions in
mm. Noise level measured at 1 m distance with in/outletspiped.Toleranceongiven values
10% - unbinding and can be changedwithout prior notice.
LATERAL CHANNEL BLOWERS - EXHAUSTERS
SCL 06 MOR
SN 1750-0
L
1”
220
18
1
222
160
7
27
M5
x12
°
1
4.
11
11
111
1
11
Kilianstraße 142
90425 NÜRNBERG
Tel. 0911.36.76.68.00
Fax 0911.36.76.68.01
E-maildeutschland@fpz.com
Version “P”
B
C