ENGLISH
Defrosng operaon
The evaporator in the dehumidier may defrost automacally if it is operated in
the room temperature less than 18°C. The defrosng process may start up and operate for some me
(about 5 minutes) automacally every 25 minutes or even
longer.-During the defrosng operaon, the dehumidificaon funcon and
air purificaon funcon may intermit. Please don’t turn o the switch or pull
out the power plug of the dehumidier during the defrosng operaon.
This de
humidie
r can’t be applicable to keep extreme low temperature.
The purpose of the dehumidier is to pump o the unpleasant high humidity
in daily life and dry the wet things.
But it can’t be used to keep extreme low temperature
Defrost pro
cedure
Please note if the ROOM temperature is less than 24, the unit will start defrost funcon!
24°C: no defrost
18-23°C 2hours dehumidify then 5minute defrost, cycle;
12-18°C: 25minute dehumidify then 5minute defrost, cycle;
5-12°C: 20minute dehumidify then 5minute defrost, cycle; 5-12°C
5°C: unit protecon, compressor of, fan of. All operaon mode cannot be acvated except air circulaon
mode
.
Erro
code
Touble Shoong
FL
water full
E2
temp. sensor erro
LO
working temp. is low, it is normal
phenomenon
HI
working temp. is high, it is normal
phenomenon
P1
unit is in defrost mode