Parameter Specification Unit QA Test Limits Conditions Notes
Protection
Short Circuit Protection YES --
Functional Direct short at output
Thermal Protection 65 deg. C --
Functional @1/8 max unclipped Power
Temperature rise should not exceed 35K
rise
DC Offset Protection YES --
Functional DC present at Speaker Out leads Relay or crowbar (for driver/fire protection)
Line Fuse Rating
External fuse with UL/SEMKO rated holder
120 VAC 2.5 Amps
Type-T or Slo Blo, Fuse markings T2.5A,
250V
230 VAC 1.25 Amps
Type-T, Low breaking capacity, Fuse
markings T1.25AL, 250V