Why is my Ingersoll-Rand Air Compressor drawing high current?
- TTammy MooreAug 19, 2025
High current draw in your Ingersoll-Rand Air Compressor can occur due to several reasons. It might be that the compressor is operating above its rated pressure, in which case you should set the pressure to the correct rating for the machine. Other causes include a contaminated separator cartridge (change the air filter and separator cartridge), low voltage (ensure voltage does not drop below 10% on start up and 6% running), unbalanced voltage (correct the incoming supply voltage), a damaged airend (change the airend), or contaminated compressed air filters (replace the air filters).