This manual contains important safety information.
Do not destroy this manual.
This manual must be available to the personnel who operate and maintain this machine.
OPERATION & MAINTENANCE MANUAL
LIGHT TOWER MODELS
L6 L8 Lightsource/HA
CODE: C CODE: C CODE: A
Revised (10-12)
Doosan purchased Bobcat Company from Ingersoll-Rand Company in
2007. Any reference to Ingersoll-Rand Company or use of trademarks,
service marks, logos, or other proprietary identifying marks belonging
to Ingersoll-Rand Company in this manual is historical or nominative
in nature, and is not meant to suggest a current affiliation between
Ingersoll-Rand C
ompany and Doosan
Company or the products of
e
ith
er.

Questions and Answers

  • M
    Michael AcostaAug 17, 2025
    Why does my Ingersoll-Rand L6 unit shutdown?
    • A
      Amanda JonesAug 17, 2025
      If your Ingersoll-Rand Lighting Equipment unit shuts down, there are several potential causes. It could be as simple as being out of fuel, so check the fuel level first. Other possibilities include low engine oil pressure (check the oil level and pressure) or the engine temperature being too high (check the cooling system). A broken engine fan belt, loose wire connection, defective fuel solenoid, malfunctioning relay, or blown fuse could also be responsible. Finally, the engine itself might be malfunctioning, requiring diagnostics. Inspect and replace the fan belt, secure electrical connections, replace the fuel solenoid, check and replace the relay and inspect and replace blown fuses as necessary.
  • H
    hwallaceAug 20, 2025
    Why is there no generator voltage output from my Ingersoll-Rand L6 Lighting Equipment?
    • D
      Dr. Nathaniel Phillips Jr.Aug 20, 2025
      If your Ingersoll-Rand Lighting Equipment has no generator voltage output, the main circuit breaker might be off, so turn it on. Also, check for loose or intermittent wires and secure all wire connections. An electrical output overload could also be the cause, so reduce the electrical load on the generator. Other potential issues include low engine power (ensure the engine is operating properly), incorrect electrical connections (check and correct them), a defective generator diode bridge assembly (inspect and replace the diode bridge), or a defective generator (inspect and replace the generator).
  • A
    Angel WilliamsAug 25, 2025
    Why does the engine oil pressure lamp stay on in my Ingersoll-Rand Lighting Equipment?
    • M
      Matthew FieldsAug 25, 2025
      If your Ingersoll-Rand Lighting Equipment's engine oil pressure lamp stays on, it could be due to a few reasons. First, check the oil level and refill if it's low. Make sure the unit is level, as being out of level by more than 15 degrees can cause this issue. Using the wrong lube oil can also trigger the lamp, so replace it with the correct type. A defective switch may also be the cause, so inspect and replace the oil pressure switch. Finally, the engine itself might be malfunctioning, requiring necessary diagnostics.
  • N
    Nicholas JonesAug 28, 2025
    Why does the engine temperature lamp stay on in my Ingersoll-Rand Lighting Equipment?
    • J
      jonesgaryAug 28, 2025
      If the engine temperature lamp stays on in your Ingersoll-Rand Lighting Equipment, it could be due to several factors. Check for a loose or broken engine fan belt and replace it if necessary. High ambient temperature or dirty operating conditions can also cause this, so ensure the unit is operating in a suitable temperature range and clean the engine and surrounding area. A dirty radiator can restrict airflow, so clean the radiator fins. Finally, an electrical output overload could be the cause, so reduce the electrical load on the generator.
  • D
    daviswilliamSep 4, 2025
    Why is there a high/low generator voltage output from my Ingersoll-Rand Lighting Equipment?
    • J
      Jeremy RichardsSep 4, 2025
      If your Ingersoll-Rand Lighting Equipment has a high or low generator voltage output, it could be caused by several factors. Check and correct any incorrect electrical connections. Ensure the engine speed is properly adjusted to the recommended setting. Unstable engine speed (oscillation) can also lead to voltage issues, so check for mechanical problems affecting engine stability. Additionally, unstable electrical requirements, low engine power, loose or intermittent wire connections, or a defective generator diode bridge assembly could be the cause. Stabilize the load on the generator, ensure the engine is operating properly, check and secure all wire connections and inspect and replace the diode bridge as needed.
  • E
    Elizabeth LarsonSep 8, 2025
    What to do if the main circuit breaker cannot be reset on my Ingersoll-Rand L6?
    • A
      Austin SchultzSep 8, 2025
      If the main circuit breaker of your Ingersoll-Rand Lighting Equipment cannot be reset, it might be due to loose or intermittent wire connections. Inspect and secure all connections. Another cause could be an incorrect electrical connection, so check and correct the connections. Finally, the main breaker itself could be defective, so inspect and replace it if necessary.
  • T
    Tiffany RichardsonNov 11, 2025
    What to do if my Ingersoll-Rand L6 Lighting Equipment won’t start/run?
    • J
      Jennifer SchroederNov 12, 2025
      If your Ingersoll-Rand Lighting Equipment won't start or run, it could be due to several reasons. You might have low battery voltage, so try charging or replacing the battery. A blown fuse could also be the culprit, so inspect and replace any blown fuses. Other potential causes include a malfunctioning engine start switch (inspect and replace it), clogged fuel filters (clean or replace them), or simply being out of fuel (check the fuel level). Also, a defective fuel solenoid or relay could be the problem, so inspect and replace them if needed. Finally, check for loose wire connections, high engine water temperature, low engine oil pressure, or defective switches, and address accordingly. If none of these solve the issue, the engine itself might be malfunctioning, requiring necessary engine...
  • M
    Michelle AllenDec 1, 2025
    Why is the generator frequency/voltage fluctuating and/or engine oscillating in my Ingersoll-Rand Lighting Equipment?
    • C
      Catherine AdamsDec 1, 2025
      If your Ingersoll-Rand Lighting Equipment exhibits fluctuating generator frequency/voltage or an oscillating engine, it could be due to several reasons. Unstable electrical requirements can cause this, so try to stabilize the load on the generator. Unstable engine speed (oscillation) could also be the culprit, so check for mechanical issues affecting engine stability. Other potential causes include incorrect engine speed adjustment (adjust to the recommended setting), low engine power (ensure the engine is operating properly), electrical output overload (reduce electrical load), clogged air/fuel filters (clean or replace), loose or intermittent wire connections (check and secure), incorrect electrical connections (check and correct), main circuit breaker(s) being off (turn them on), or a d...

Summary

Foreword

Safety

Safety Precautions and General Information

General safety precautions, warnings, and machine suitability for different environments.

Grounding and Hazardous Materials

Grounding requirements and hazardous substances used in or produced by the machine.

Battery, Radiator, and Transport Safety

Safety guidelines for battery handling, radiator maintenance, and machine transport.

Towing Safety Procedures

Procedures and safety requirements for towing the unit.

Safety Chains, Welding, and Decal Information

Safety for chains, welding, and explanations of hazard warning decals.

General Data

Operating Instructions

Lifting Instructions

Step-by-step instructions for safely lifting and moving the light tower.

L6 Model Operation and Controls

Detailed operation and control panel descriptions for the L6 model.

L8 Model Operation and Controls

Detailed operation and control panel descriptions for the L8 model.

Lightsource;HA Controls Overview

Description of the control panel and instruments for Lightsource/HA models.

Manual Winch Operation

Instructions for manual operation, setup, and raising/lowering the tower.

Electric Winch Operation

Instructions for operating the optional electric winch system for tower movement.

Pre-Start, Starting, and Stopping Procedures

Essential checks before starting, starting sequence, and safe stopping procedures.

Maintenance

Routine Maintenance and Electrical Checks

Daily, weekly, and monthly maintenance tasks including electrical and grounding checks.

Hoses, Air System, Tires, and Fuel;Water Separator Maintenance

Maintenance of hoses, air intake, fuel/water separator, and tires.

Radiator, Cables, Pins, and Guides Maintenance

Maintenance of radiator, tower cables, locking pins, and guides.

System Protection and Component Checks

Checking shutdown systems, control compartment, fuel tank, and battery.

Fastener, Running Gear, and Instrument Maintenance

Checks for fasteners, running gear wear, and instrument functionality.

General Cleaning and Exterior Finish Repair

Guidelines for cleaning the unit and repairing its exterior finish.

Interior Cleaning Procedures

Procedures for cleaning the generator interior and control box.

Trouble Shooting

Trouble Shooting Introduction and Action Plan

Overview of troubleshooting, action plan, and diagnostic strategies.

Trouble Shooting Chart and Corrective Actions

Chart of common problems, causes, and corrective actions for unit malfunctions.