EasyManua.ls Logo

Ingersoll-Rand Lightsource/HA - User Manual

Ingersoll-Rand Lightsource/HA
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Doosan Infracore Portable Power
1293 Glenway Drive
Statesville, N.C. 28625
www.doosanportablepower.com
Book: 22924369 (3-09) Rev A
This manual contains important safety information.
Do not destroy this manual.
This manual must be available to the personnel who operate and maintain this machine.
OPERATION & MAINTENANCE MANUAL
LIGHT TOWER MODELS
L6 L8 Lightsource/HA
CODE: C CODE: C CODE: A
Revised (10-12)
Doosan purchased Bobcat Company from Ingersoll-Rand Company in
2007. Any reference to Ingersoll-Rand Company or use of trademarks,
service marks, logos, or other proprietary identifying marks belonging
to Ingersoll-Rand Company in this manual is historical or nominative
in nature, and is not meant to suggest a current affiliation between
Ingersoll-Rand C
ompany and Doosan
Company or the products of
e
ith
er.

Questions and Answers

  • D
    Danielle WilcoxAug 17, 2025
    Why does my Ingersoll-Rand Lightsource/HA Lighting Equipment unit shutdown?
    • C
      crystalleeAug 18, 2025
      If your Ingersoll-Rand Lighting Equipment unit shuts down, there are several potential causes. It could be as simple as being out of fuel, so check the fuel level first. Other possibilities include low engine oil pressure (check the oil level and pressure) or the engine temperature being too high (check the cooling system). A broken engine fan belt, loose wire connection, defective fuel solenoid, malfunctioning relay, or blown fuse could also be responsible. Finally, the engine itself might be malfunctioning, requiring diagnostics. Inspect and replace the fan belt, secure electrical connections, replace the fuel solenoid, check and replace the relay and inspect and replace blown fuses as necessary.
  • R
    Robert StarkAug 21, 2025
    Why is there no generator voltage output from my Ingersoll-Rand Lighting Equipment?
    • M
      Michael CohenAug 21, 2025
      If your Ingersoll-Rand Lighting Equipment has no generator voltage output, the main circuit breaker might be off, so turn it on. Also, check for loose or intermittent wires and secure all wire connections. An electrical output overload could also be the cause, so reduce the electrical load on the generator. Other potential issues include low engine power (ensure the engine is operating properly), incorrect electrical connections (check and correct them), a defective generator diode bridge assembly (inspect and replace the diode bridge), or a defective generator (inspect and replace the generator).
  • S
    selena75Aug 25, 2025
    Why does the engine oil pressure lamp stay on in my Ingersoll-Rand Lightsource/HA?
    • G
      Gary CarterAug 26, 2025
      If your Ingersoll-Rand Lighting Equipment's engine oil pressure lamp stays on, it could be due to a few reasons. First, check the oil level and refill if it's low. Make sure the unit is level, as being out of level by more than 15 degrees can cause this issue. Using the wrong lube oil can also trigger the lamp, so replace it with the correct type. A defective switch may also be the cause, so inspect and replace the oil pressure switch. Finally, the engine itself might be malfunctioning, requiring necessary diagnostics.
  • D
    donaldgonzalesAug 28, 2025
    Why does the engine temperature lamp stay on in my Ingersoll-Rand Lightsource/HA Lighting Equipment?
    • J
      Jenna RobersonAug 28, 2025
      If the engine temperature lamp stays on in your Ingersoll-Rand Lighting Equipment, it could be due to several factors. Check for a loose or broken engine fan belt and replace it if necessary. High ambient temperature or dirty operating conditions can also cause this, so ensure the unit is operating in a suitable temperature range and clean the engine and surrounding area. A dirty radiator can restrict airflow, so clean the radiator fins. Finally, an electrical output overload could be the cause, so reduce the electrical load on the generator.
  • P
    Peter MeyerSep 5, 2025
    Why is there a high/low generator voltage output from my Ingersoll-Rand Lightsource/HA Lighting Equipment?
    • M
      Michael JohnsonSep 5, 2025
      If your Ingersoll-Rand Lighting Equipment has a high or low generator voltage output, it could be caused by several factors. Check and correct any incorrect electrical connections. Ensure the engine speed is properly adjusted to the recommended setting. Unstable engine speed (oscillation) can also lead to voltage issues, so check for mechanical problems affecting engine stability. Additionally, unstable electrical requirements, low engine power, loose or intermittent wire connections, or a defective generator diode bridge assembly could be the cause. Stabilize the load on the generator, ensure the engine is operating properly, check and secure all wire connections and inspect and replace the diode bridge as needed.
  • D
    David CarlsonSep 9, 2025
    What to do if the main circuit breaker cannot be reset on my Ingersoll-Rand Lighting Equipment?
    • A
      Alexis ParkerSep 9, 2025
      If the main circuit breaker of your Ingersoll-Rand Lighting Equipment cannot be reset, it might be due to loose or intermittent wire connections. Inspect and secure all connections. Another cause could be an incorrect electrical connection, so check and correct the connections. Finally, the main breaker itself could be defective, so inspect and replace it if necessary.
  • M
    Michael LaneNov 12, 2025
    What to do if my Ingersoll-Rand Lighting Equipment won’t start/run?
    • R
      reyesmatthewNov 12, 2025
      If your Ingersoll-Rand Lighting Equipment won't start or run, it could be due to several reasons. You might have low battery voltage, so try charging or replacing the battery. A blown fuse could also be the culprit, so inspect and replace any blown fuses. Other potential causes include a malfunctioning engine start switch (inspect and replace it), clogged fuel filters (clean or replace them), or simply being out of fuel (check the fuel level). Also, a defective fuel solenoid or relay could be the problem, so inspect and replace them if needed. Finally, check for loose wire connections, high engine water temperature, low engine oil pressure, or defective switches, and address accordingly. If none of these solve the issue, the engine itself might be malfunctioning, requiring necessary engine...
  • S
    scottmillerDec 3, 2025
    Why is the generator frequency/voltage fluctuating and/or engine oscillating in my Ingersoll-Rand Lightsource/HA Lighting Equipment?

    Summary

    Foreword

    Safety

    Safety Precautions

    Essential safety rules and guidelines for operating the unit.

    Materials and Hazards

    Information on hazardous materials and associated risks.

    Operation Safety

    Safety measures for battery, radiator, and transport.

    Towing Safety

    Guidelines for safe towing of the unit.

    Decal Information

    Understanding the meaning of safety decals.

    General Data

    Operating Instructions

    Lifting Instructions

    Procedures for safely lifting the light tower unit.

    L6 Operation

    Operating controls and instruments for the L6 model.

    Winch Operation

    Instructions for manual and electric winch operations.

    Pre-Operation and Start

    Steps to perform before starting the unit, including starting procedure.

    Stopping Procedures

    Steps for safely shutting down the unit.

    Maintenance

    Routine Maintenance

    Daily, weekly, and monthly maintenance tasks for proper unit upkeep.

    Hoses and Fuel System

    Inspection and maintenance of hoses and fuel/water separator.

    Engine Radiator and Cooling

    Maintenance of the engine radiator and coolant system.

    Engine Protection System

    Checking the operation of engine protection shutdown systems.

    Running Gear and Fasteners

    Maintenance of wheel bearings, seals, and fasteners.

    Trouble Shooting

    Introduction and Action Plan

    Overview of troubleshooting approach and systematic steps to diagnose issues.

    Trouble Shooting Chart

    Common problems, causes, and corrective actions.

    Ingersoll-Rand Lightsource/HA Specifications

    General IconGeneral
    BrandIngersoll-Rand
    ModelLightsource/HA
    CategoryLighting Equipment
    LanguageEnglish

    Related product manuals