8
Technical Specications
Applicable ber type
SM(ITU-T G.652&G.657) / MM(ITU-T G.651) / DS(ITU-T G.653)
/ NZDS(ITU-T G.655)
Fiber count: Single
Applicable ber cables: 0.25mm - 3.0mm / Indoor cable
Applicable ber diameter: Cladding diameter: 80~150μm,
Coating diameter: 125~1000μm
Splice loss
Measured by cut-back method relevant to ITU-T standard:
SM : 0.03dB
MM : 0.02dB
DS : 0.05dB
NZDS : 0.05dB
G.657 : 0.03dB
Splice mode
Maximum 128 splice modes
Internal splice data storage: 10,000
Splicing time: SM Quick mode: 7s
Heat oven
5 applicable protection sleeve: 20mm, 30mm, 40mm, 50mm, 60mm
Heating time: 8- 900s
Typical heating time: 30s
Heat mode: Various heat modes available
Heat oven: VIEW 3 special heat oven
1