AMTEK Version 7.4 2019-01 Page 28 ©Inomatic 2017-2019
Two AM Processor antennas that are NOT synchronized
The TX pulse of system 2 starts later than the TX pulse of system 1, resulting in the fact
that system 1 is receiving the TX pulse of system 2 in its receiver window. This might
create false alarms and poor detection on system 1, whereas system 2 will function
properly as the TX pulse of system 1 is not affecting the receiver window of system 2.
This problem can be solved by making sure that both systems transmit and receive at
the same moment, which can be realized by changing the Syncron” value time for one
of the two systems using InfoNet software.
Please note that any TX pulse should also not fall into to the Reference window LS 2 as
it would push up the noise level of the system dramatically. The system may not alarm
but the performance will be affected.
TX PULSE
TX PULSE
LS 1
LS 1
LS 2
TX PULSE
TX PULSE
LS 1
LS 1
LS 2
Antenna 2
Antenna 1