EasyManua.ls Logo

InoTec CLS 24.1-7Ah User Manual

InoTec CLS 24.1-7Ah
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
Sicherheitstechnik GmbH
Mounting- and Operating Instructions
Emergency Lighting Device
CLS 24.1 - 7Ah
CLS 24.1
CLS 24.1 - Power
Montage- und Betriebsanleitung
Notlichtversorgungsgerät
CLS 24.1 - 7Ah
CLS 24.1
CLS 24.1 - Power

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the InoTec CLS 24.1-7Ah and is the answer not in the manual?

InoTec CLS 24.1-7Ah Specifications

General IconGeneral
BrandInoTec
ModelCLS 24.1-7Ah
CategoryLighting Equipment
LanguageEnglish

Summary

General Information

Explanation of symbols

Explains symbols used in the manual for safety and important information.

Liability and warranty

Outlines INOTEC's warranty limitations and liability exclusions.

Spare parts

Specifies that only original INOTEC spare parts must be used for replacement.

Disposal

Provides guidance on how to dispose of batteries and electronic components.

Correction of faults

Details the procedure to reset fault indications after fixing issues.

Safety instructions

Operating instructions

Emphasizes reading instructions for safety, usage, and maintenance.

Repairs

States that repairs must only be performed by authorized INOTEC personnel.

Transport and storage

Examination on delivery

Instructs to check the device for damage and completeness upon receipt.

Storage

Provides guidelines for storing the device to maintain its condition.

Product description

Design and structure of CLS devices

Describes the physical layout and components of the CLS system.

Technical data

CLS 24.1 - 7Ah

Lists technical specifications for the CLS 24.1 - 7Ah model.

CLS 24.1

Lists technical specifications for the CLS 24.1 model.

CLS 24.1 - Power

Lists technical specifications for the CLS 24.1 - Power model.

Mounting

Device

Explains how to unpack and access the device components.

Battery

Details the procedure for checking and connecting batteries.

Electrical connection

Mains connection

Describes how to connect the 230V AC power supply to the device.

Final circuits

Explains the system's 4 final circuits for monitoring luminaires.

Light sequence switching

Describes how to switch general and safety luminaires together.

24V current loop

Explains the function and connection of the 24V current loop for safety.

CLS mimic panel

Describes connecting multiple CLS devices to a central mimic panel.

Mimic panel

Explains connecting an external remote mimic panel to the device terminals.

InoWeb

Details how to use the InoWeb module for network monitoring.

Central dimming

Explains how to use the CLS dimmer module for central luminaire dimming.

Commissioning the CLS device

Switching OFF the CLS device

Provides the correct sequence for powering down the CLS device.

Switching ON the CLS device

Provides the correct sequence for powering up the CLS device.

Factory settings

Lists the default configuration parameters of the controller.

Use

Operation protection

Describes the system's protection against unauthorized operation.

Menu structure

Outlines the navigation and organization of the CLS system's menu.

"Test menu"

Describes how to access and perform various tests on the system.

"Programming"

Explains how to configure the CLS system settings.

"Information"

Explains how to access device and luminaire status information.

Unblock system

Describes how to release a blocked CLS device.

Troubleshooting

Fault/luminaire failure

Details how to identify and resolve luminaire failures.

Battery fault

Explains how to check for and resolve battery circuit faults.

Main-db failure

Describes the message displayed for a main distribution board power failure.

Sub-db failure

Describes the message displayed for a sub-distribution board power failure.

INOWeb

Use

Explains how to access and use the InoWeb interface.

Printing out the fault

Describes how to print fault information from the web browser.

Automatic email

Explains how to configure automatic email notifications for system events.

Programming

Describes the process of programming the InoWeb module via serial interface.

INOLan

Tests

Initial tests

Outlines the initial tests required after system setup and installation.

Recurring safety tests on electrical systems

Details recurring tests required by national guidelines.

Appendix

Copy template for system documentation

Provides a template for documenting the system configuration.

Input power charts

Wire lengths

Customer service

Related product manuals