EasyManua.ls Logo

Inovance IS620PT3R5I - User Manual

Inovance IS620PT3R5I
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Table of Contents

Questions and Answers

  • B
    Barbara Bishop MDAug 19, 2025
    What to do if the LED display is not on for Inovance Controller?
    • S
      schmidtwayneAug 19, 2025
      If the LED display of your Inovance Controller is not on or doesn't show "rdy", it could be due to several reasons. First, the control power voltage might be abnormal, so measure the AC voltage between L1C and L2C. Second, the main power voltage might be abnormal; for a single-phase 220 V model, measure the AC voltage between L1 and L2. If the DC bus voltage amplitude (voltage between P and -) is lower than 200 V, "nrd" will be displayed. Third, the program burning terminal might be shorted, so check it. Finally, the servo drive itself might be faulty.
  • J
    jonesalexanderAug 21, 2025
    Why is the shaft of my Inovance Controller's servo motor in free running status?
    • J
      John ShortAug 21, 2025
      If the shaft of your servo motor is in a free running status, ensure the S-ON signal is valid by setting the operation panel to servo status display and checking if it displays "rdy" instead of "run". Also, verify that the control mode selection is correct by checking if H02-00 is set to 1.
  • D
    davisaaronAug 25, 2025
    Why doesn't the servo motor rotate in my Inovance Controller?
    • K
      Kathryn GrahamAug 25, 2025
      If your Inovance Controller's servo motor does not rotate, it could be due to an internal torque reference (H0B-02) being 0. Check whether the polarity of the input signal is reversed.
  • M
    Mr. Anthony Baker MDAug 26, 2025
    Why is my Inovance Controller's servo motor rotating in the reverse direction?
    • N
      nicholasfisherAug 27, 2025
      If the servo motor of your Inovance Controller rotates in the reverse direction, and you're using AI to input torque reference, check whether the polarity of the external voltage input signal is reversed, as the internal torque reference (H0B-02) might be negative.
  • S
    Samantha AustinAug 28, 2025
    What causes the servo motor of Inovance Controller to not rotate or have abnormal speed?
    • M
      Michael KellerAug 28, 2025
      If the servo motor does not rotate or the motor speed is abnormal, it might be caused by incorrect AI wiring. Verify that the analog input channel is selected correctly and that the selected AI terminal is wired correctly.
  • B
    barronsarahAug 30, 2025
    How to fix unsteady motor speed on Inovance Controller?
    • G
      greenepatrickAug 31, 2025
      If the motor speed of your Inovance Controller is not steady, perform automatic gain tuning, as the gain might be set improperly.
  • A
    Amber RichardsonSep 1, 2025
    What causes the motor shaft to vibrate left and right on Inovance Controller?
    • K
      Katherine WeaverSep 2, 2025
      If the motor shaft vibrates left and right, it might be because the load inertia ratio (H08-15) is too large. Perform inertia auto-tuning and automatic gain tuning on your Inovance Controller.
  • M
    madelinewilliamsSep 4, 2025
    What to do if the servo motor of Inovance Controller does not rotate?
    • J
      James BarnettSep 4, 2025
      If your Inovance Controller's servo motor does not rotate, it could be due to the input reference pulse counter (H0B-13) being 0. Check whether the high/low-speed pulse input terminal is wired correctly. Alternatively, it could be that the position reference is not input. Check whether FunIN.13: INHIBIT (pulse input forbidden) or FunIN.37: PulseInhibit (pulse forbidden) is used.
  • J
    Jessica HarrisonSep 6, 2025
    Why does my Inovance Controller's servo motor jitter at low speed?
    • B
      Bryce FinleySep 6, 2025
      If your Inovance Controller's servo motor jitters at low speed, it might be because the motor speed is not steady. The gain may be set improperly.
  • R
    Richard ChenSep 8, 2025
    What to do if Inovance Controller's servo drive is faulty?
    • T
      Taylor MooreSep 9, 2025
      Replace the servo drive.