Questions and Answers

  • T
    Terry CrawfordAug 12, 2025
    What to do if the INOXPA Hyclean Water Pump suction pipe is clogged?
    • L
      Laurie RomanAug 12, 2025
      If the suction pipe of your INOXPA Water Pump is clogged, you should check the suction pipe and filter(s), if any, to resolve the issue.
  • C
    Cynthia BentleyAug 15, 2025
    How to fix an INOXPA Hyclean Water Pump that sucks in air?
    • B
      Bradley HodgesAug 16, 2025
      If your INOXPA Water Pump is sucking in air, check the suction pipe and all its connections to ensure they are properly sealed.
  • B
    Betty HensleyAug 19, 2025
    How to resolve motor overload in an INOXPA Water Pump?
    • M
      Michele NelsonAug 19, 2025
      To resolve motor overload in your INOXPA Water Pump, invert the rotation direction.
  • M
    mbradleyAug 23, 2025
    What to do if INOXPA Hyclean Water Pump is not purged?
    • J
      Justin BushAug 25, 2025
      If your INOXPA Water Pump is not purged, you should purge or fill it to resolve the issue.
  • D
    Daisy ClarkAug 27, 2025
    How to manage high liquid viscosity in INOXPA Water Pump?
    • G
      Gregory CastanedaAug 27, 2025
      If the viscosity of the liquid is too high in your INOXPA Water Pump, you can reduce the viscosity by, for example, heating the liquid, or reduce the pump speed.
  • C
    charles31Aug 31, 2025
    How to manage low liquid viscosity in INOXPA Hyclean Water Pump?
    • T
      tayloradamAug 31, 2025
      If the viscosity of the liquid is too low in your INOXPA Water Pump, increase the viscosity by, for example, by cooling the liquid, or increase the pump speed.
  • S
    Sarah WoodSep 3, 2025
    How to reduce high liquid temperature in INOXPA Hyclean?
    • J
      Jason WilliamsSep 3, 2025
      If the temperature of the liquid is too high in your INOXPA Water Pump, reduce the temperature by cooling the liquid.
  • B
    Benjamin CarterSep 7, 2025
    What to do if the lobes are worn in INOXPA Hyclean?
    • A
      Alyssa LozanoSep 7, 2025
      If the lobes are worn in your INOXPA Water Pump, replace the lobes.

INOXPA Hyclean Series Specifications

General IconGeneral
Surface FinishRa ≤ 0.8 μm
ApplicationsFood-processing, cosmetics, pharmaceutical and fine chemical industries
Pump TypeCentrifugal
Impeller TypeOpen impeller
MaterialStainless steel AISI 316L
Maximum Head70 m
Maximum Working Pressure10 bar
Maximum Temperature120 °C
Seal TypeSingle mechanical seal
CertificationsEHEDG certified
Hygienic DesignYes, EHEDG certified

Related product manuals