We recommend a BAR pressure between 2.5 and 3.4 BAR. If
you have a combi boiler system no problem should be
experienced. If you have a gravity feed older type installaon
(hot water tank type usually less than 1 BAR) you will almost
certainly need a pump. We cannot advise on which type of
pump is used, locaon or design because all house plumbing
layouts vary. This is a job for your installer/plumber. The end
delivery however must fall within the scope above.
Important Note Do not exceed 3.4 BAR pressure under any
circumstances. Warranty is void if so as damage will occur. If
you have a combi supply, please use a pressure reducing valve
if required to lower the BAR pressure to the shower.
Please Remember that this product is free standing and is
designed to be pulled away from the wall.
The waste hose must be of a exible type (1m exible waste
supplied).
The water supply pipes must be that of a exible braided type
(not supplied).
DO NOT OVERTIGHTEN THE BRAIDED HOSES AS IT CAN CAUSE
THE CONNECTION TO POP AFTER A FEW WEEKS OF USE.
Always t easy to get to isolaon taps on both hot and cold
water supply (not supplied). Just like a dishwasher or washing
machine, this product MUST be isolated when not in use.
Scissors
Knife
Spirit Level
Tape Measure
Pressure/Water Requirements Tools Required
RubberGum (supplied)
Plumbers Mait (not supplied)
Hot and cold isolaon valves (not supplied)
2x Braided hoses (not supplied) Steam version
requires 3. If you havent purchased these already,
simply click the following link below or copy in to
any web browser. For ease we have listed the
required pack below for your install.
Shower cabins require pack 1
Shower cabins with steam require pack 2
hps://www.insigniashowers.com/wras-approved-
braided-hoses.html
Parts Required
STEAM VERSION
Voltage Rang 220-240AC
Frequency Rang 50Hz
Power Rang 3KW
NON-STEAM VERSION
Voltage Rang 100-240AC
Frequency Rang 50/60Hz
Power Rang 12v DC/1500 mA
Your electrical contractor should understand ALL legal
requirements of connecon before undertaking any work
or installaon.
UNDER NO CIRCUMSTANCES UNDERTAKE THIS
YOURSELF!!!
Note for electrician: This product comes with 13 amp plug
(s) ed with an RCD unit (steam version only). We leave it
this way for you to connect it your own way due to
connued addions to current regulaons.
1) Connect within current laws and IP direcves.
2) (Preferred) Wire into isolated fused feed connecng
directly to the house consumer/service box.
Always use protecon against electrical surge. Your shower
should be treated the same as a home computer. A surge
protector should eradicate the possibility of either the
transformer or control panel being burnt out. Electrical
work needs to be signed o by a fully qualied operave by
law. Failure to adhere to this will not only void your
electrical warranty for your shower, but could void your
house insurance too.
Electrical Requirements
You will require:
Philips Screwdriver
Electric Drill
Safety Gloves
Safety Glasses