PART 5 MAINTENANCE & REPAIR PROCEDURES
20
®
TROUBLESHOOTING
TECHNICAL ISSUES
POSSIBLE CAUSES SOLUTIONS
Tank not lling/tank heat
coming on with no water in
tank
1. Level oat dirty
2. Level control system not working
1. Clean level oat
2. Troubleshoot level control circuit
Tank temperature too low/high 1. Thermostat not adjusted
2. Heat circuitry not working
3. Electric heat - power turned o󰀨
4. Electric heat - immersion heaters
limed
5. Steam heat - steam turned o󰀨
6. Steam heat - not enough steam
7. Steam heat - condensate traps
clogged
8. Gas heat - gas turned o󰀨
9. Gas heat - pilot not lit (if provided)
1. Adjust thermostat
2. Troubleshoot circuitry
3. Check circuit breakers
4. De-lime machine
5. Turn steam on
6. Adjust steam pressure per machine
specs
7. Clean or replace condensate traps
8. Turn on gas
9. Re-light pilot