PART 5 MAINTENANCE & REPAIR PROCEDURES
20
®
TROUBLESHOOTING
TECHNICAL ISSUES
POSSIBLE CAUSES SOLUTIONS
Tank not lling/tank heat
coming on with no water in
tank
1. Level oat dirty
2. Level control system not working
1. Clean level oat
2. Troubleshoot level control circuit
Tank temperature too low/high 1. Thermostat not adjusted
2. Heat circuitry not working
3. Electric heat - power turned o
4. Electric heat - immersion heaters
limed
5. Steam heat - steam turned o
6. Steam heat - not enough steam
7. Steam heat - condensate traps
clogged
8. Gas heat - gas turned o
9. Gas heat - pilot not lit (if provided)
1. Adjust thermostat
2. Troubleshoot circuitry
3. Check circuit breakers
4. De-lime machine
5. Turn steam on
6. Adjust steam pressure per machine
specs
7. Clean or replace condensate traps
8. Turn on gas
9. Re-light pilot
CA-3 & DA-3 Technical Manual 2018 www.insingermachine.com 800-344-4802