3. Align a at screw-driver or similar with the tab
on the lter and gently push.
4. With one tab loosened, pull the lter cap off
the old cartridge.
5. Align the shape on the inside of the lter cap
(highlighted above) with the shape on the end
of the new lter and push the two together
until it clicks rmly in place.
6. Remove protective cap from the top of the
new cartridge and ensure the two rubber
seals are in place.
7. Insert new cartridge and turn until it locates.
Install with a quarter-turn to the right until
cartridge comes to a complete stop (Inlet
water will automatically turn on).
8. Switch boiler back on and allow to ll
(15 minutes)