Service Warnings And Fault
Diagnosis
Your boiler is tted with an intelligent fault
diagnosing system and is able to detect various
fault conditions. Some of these are less serious
and the machine will continue to operate as
normal, while others are more serious and will
disable the unit.
Before calling for service, switch the machine off
at the mains supply. Draw-off a small amount of
water and then switch back on after 10 minutes.
If the fault does not clear, call technical support
for advice.
8
Filter cartridge is
exhausted and
should be
replaced as soon
as convenient
Water turned o
Inlet hose
kinked or bent
Low incoming
water pressure
Low water level
probe scaled up
Over-boil safety
switch tripped on
initial heat-up
Faulty element
Boil dry safety
switch tripped
Replacement lter
cartridge available
from Instanta
Spares
Part no: AQ35
Check water supply
and stop-cock
Check incoming
water is at
minimum of 2 bar
De-scale
Isolate machine
and wait for 10
minutes, then turn
back on again
Call service if fault
persists
De-scale
Reduce
temperature
setting
Call service if fault
persists
Over-boiled when
in ‘Ready ‘ mode
due to excessive
limescale in tank
Temperature
sensor
disconnected
or wires cut
SCREEN MESSAGE POSSIBLE CAUSES ACTION
READY
CHANGE
FILTER
NOT
READY
HEATING
!!
NOT
READY
HEATING
!!
READY
! CLEAN PROBES !
READY
! CHECK WATER !
FLASHING
RED SCREEN
FLASHING
RED SCREEN WHITE SCREEN WHITE SCREEN WHITE SCREEN