Cleaning
Clean the external surfaces of the boiler
regularly to maintain good hygiene.
Empty the front drip-tray regularly.
Wipe external surfaces of the boiler with a damp
cloth. Do not use abrasive materials on the outer
surfaces.
Wipe the draw-off tap each day to keep clean
and also prevent lime-scale deposits from
building up around the tap-outlet.
Maintenance & Service
Information
Filter:
Twist to the left and remove. See “AQ35 Filter
Replacement” section above.
Descaling:
The boiler should be periodically checked for
scale build-up…see below:
In hard water areas, the boiler should be
descaled on a regular basis to maintain efcient
operation, minimise energy consumption, and
also retain the water quality. The frequency
depends on the hardness of the local mains
water supply and the regular replacement of the
AQ35 lter cartridge.
To de-scale:
Disconnect machine from power supply
Empty the machine through the draw-off tap
and allow to cool
Remove outer-lid (spring-clips).
Remove tank-lid (four/six xing screws).
Lift out the evaporation plates
(inside of tank – Remember order
of removal).
Remove as much scale as possible by hand.
Any scale which is difcult to remove can be
dissolved by using a de-scaling solution.
Wipe clean the level sensing probes.
Flush with copious amounts of cold water to
ensure all traces of de-scaler are removed
before using the boiler again.
Replace evaporation plates, tank-lid and
outer lid.
Draw-off tap:
The tap spring and washer components are
subject to wear & tear. It is advisable to keep
a spare tap-spring and washer in case of
emergencies.
Accessories & Spares (Tel: 01704 502905)
Replacement Tap Washer: TP1001/L
Replacement Tap Spring: TP1007/N
Replacement Filter Cartridge: AQ35
Drip-tray overow Kit DTK2
(connection to perm waste):
A full range of spares and accessories are
available from our spares department.