EasyManua.ls Logo

Instek Digital LCR-819 User Manual

Instek Digital LCR-819
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
LCR-800 Series User Manual
i
CONTENTS PAGE
1. INTRODUCTION……………………………………..……... 1
2. PRECAUTIONS BEFORE OPERATION…….…………….
2-1.Unpacking the instrument………………….…………….
2-2.Checking the Line Voltage…………………..……………
2-3.Environment……………………………………..………..
2-4.Equipment Installation and Operation…………………
2
2
2
3
3
3. PANEL DESCRIPTION…...……………………..………….. 4
OPERATION…………….………………………………...….
4-1.Connects to DUT….………………..………….……..…...
4-2.Start-Up……….....……………………………..………….
4-3.Zeroing…………………………………………………….
4-4.Menu Functions.…..………………………………………
4-5.Measurement Conditions…..……………………………..
8
8
8
8
11
18
4.
5.
SPECIFICATIONS…………………………………………...
35
6. MESSAGE CODE.………………………………………….... 44
7. MAINTENANCE....…………………………………………...
7-1.Cleaning……………………………………………………
7-2.Battery Replacement……………………………………...
7-3.Recall Calibration………………………………………...
45
45
45
46
8. OPTION 1 (BIN Function for LCR-826/827/829 only)……..
8-1. BIN Functions for Components Sorting……………..….
8-2. BIN Setting Conditions.....……………………………….
8-3. BIN Range Setting: Component Sorting Range..............
48
48
50
56
9. OPTION 2……………………………………………………..
9-1.On-line procedure…………………………………………
9-2.RS232 VIEWER Software Operation…………………...
9-3.The Configuration of Cable………………………………
65
65
69
74
LCR-800 Series User Manual
ii
SAFETY TERMS AND SYMBOLS
These terms may appear in this manual or on the product:
WARNING: Warning statements identify condition or practices
that could result in injury or loss of life.
CAUTION: Caution statements identify conditions or practices
that could result in damage to this product or other property.
The following symbols may appear in this manual or on the product:
DANGER ATTENTION Protective Frame or Chassis
High Voltage refer to Manual Conductor Terminal
Terminal
Question and Answer IconNeed help?

Do you have a question about the Instek Digital LCR-819 and is the answer not in the manual?

Instek Digital LCR-819 Specifications

General IconGeneral
TypeDigital LCR Meter
Test Frequency100Hz, 120Hz, 1kHz, 10kHz, 100kHz
Basic Accuracy0.1%
Output Impedance100Ω
Equivalent Circuit ModeSeries, Parallel
Frequency Range100Hz to 100kHz
Accuracy±0.1%
Test Signal Level0.3Vrms, 1.0Vrms
DisplayLCD with backlight
Measurement ParametersL, C, R, D, Q, θ
InterfacesUSB, RS-232
Output InterfaceUSB
Measurement Speed3 times per second
Power SupplyAC 100V to 240V, 50/60Hz

Summary

Safety Terms and Symbols

Precautions Before Operation

Operation

Basic Operation and Zeroing Procedures

Steps for connecting the DUT, starting up the instrument, and performing open/short circuit zeroing for accuracy.

Menu Functions and Measurement Settings

Overview of menu-driven functions, including parameter selection, measurement modes, and condition settings like frequency, voltage, and speed.

Specifications

Maintenance

Option 1: BIN Functions

BIN Functions for Component Sorting

Setup and usage of the BIN function for sorting components based on measurement criteria.

Option 2: RS-232C Communication

On-line Procedure

Steps to establish an on-line connection between the LCR meter and a computer using RS-232C.

Related product manuals