TroubleShooting
Problem
Likely Cause
Remedy
Machine does not turn on.
Power cord connection is loose.
Ensure appropriate power cord
connection at machine.
Ensure appropriate power cord
connection at power source.
POWER ON BUTTON not in on
position.
Press POWER ON BUTTON in for
it to light up green.
ROTARY CONTROL SWITCH not
in desired position.
Rotate ROTARY CONTROL
SWITCH to the location you
desire for system control. Then
utilize appropriate remote is
selected wired or wireless.
Power cord not connected at
machine or power source.
Connect power cord.
Machine’s circuit breaker has
tripped.
Reset circuit breaker(s).
Circuit breaker at power source
has tripped.
Reset circuit breaker.
Electrical system may have a
loose wire.
Contact Intec Tech Support
Wired remote cord & electrical
panel switches need to be in
‘ON’ position for machine to
turn on.
Place the electrical panel
blower and agitator switches in
the ‘ON’ position. Place the
remote’s blower switch in the
‘ON’ position; place the
remote’s agitator switch in the
‘ON’ position.
Blower does not run.
Blower’s circuit breaker needs
to be reset.
Reset blower circuit breaker.
Faulty Blower motor
Contact Intec Tech Support
Problem
Likely Cause
Remedy
Agitator does not run.
Blower has to be on for agitator
to come on.
Turn blower on.
Agitator circuit breaker needs
to be reset.
Ensure agitator circuit breaker
is reset.
Foreign material causing jam in
hopper.
Remove power cords, clear jam,
and restart system.