8 Intel Desktop Board DP965LT Specification Update
Errata
1. Doing extended Boot Cycling will occasionally observe board hang at POST code 46
PROBLEM: When doing Boot Cycling testing the board can experience a hard hang at
POST Code 46
IMPLICATION: If the board fails during Boot cycling due to this erratum the customer
will observe a hung system and will need to reset the system to continue.
WORKAROUND: None
STATUS: Fixed in BIOS MQ96510J.86A.0816.
2. Intel
®
Quiet System Technology fails to initialize properly
PROBLEM: Intel Quiet System Technology fails to initialize and max fan speed
results
IMPLICATION: If the ME-HECI controller fails to initialize correctly then the Intel
Quiet System Technology will not work and the customer will experience increase
system sound levels.
WORKAROUND: None
STATUS: Fixed in BIOS MQ96510J.86A.0816.