101
Events of the restoration type
Sensor tamper
Zone no. Event Contact-ID Code
01 to 64 Sensor tamper restoration 383
Use the table above to carry out the
Contact-ID
event change command for zone
sensor tamper restoration, as described below:
912
+
Enter Enter
+ +
Zone N°
01 to 64
After entering the command, enter the event value in hexadecimal format from
000 to FFF (accepts numbers from 0 to 9 and the letters B, C, D, E and F) and press
the
Enter
key to conrm. If you only want to view the setting, press the
Exit
key and
no programming will be changed.
Events of the opening type
User Deactivation
User no. Event Contact-ID Code
01 to 97 User Deactivation 401
Use the table above to perform the
Contact-ID
event change command to
deactivate each registered user, as described below:
903
+
Enter Enter
+ +
User N°
01 to 97
After entering the command, enter the event value in hexadecimal format from
000 to FFF (accepts numbers from 0 to 9 and the letters B, C, D, E and F) and press
the
Enter
key to conrm. If you only want to view the setting, press the
Exit
and no
programming will be changed.
Events of the restoration type
User Activation
User no. Event Contact-ID Code
01 to 97 User Activation 401