142
Note:
for XAS 8000 and TX 8000 the Sensitivity, Sensor LED andOperation
Mode settings are allowed by the unit, but only the LED conguration is
accepted by XAS 8000 and TX 8000.
» Wireless sensor testing
Enter + 52 + Enter + Activate sensor
» Wireless siren
» Register wireless sirens
Enter + 621 + NS + Enter + Activate the siren
by pressing the synchronisation
key
NS = siren number from 01 to 16.
» Delete wireless sirens
Enter + 721 + NS + Enter
NS = siren number from 01 to 16.
» Wireless siren partition
Enter + 222 + NS + PP + Enter
NS = siren number from 01 to 16.
PP = partition from 00 to 16 (00 = common address for all zones and 01 to 16
the individual center partitions).
» Enable/disable the siren beep on system activation/deactivation
Enter + 510 + Enter + Key 3 + Enter
» Enable/disable the siren beep per partition
Enter + 224 + GP + Enter
GP = group of partitions, with partitions 01 to 10 in group 0 and partitions 11
to 16 in group 1.
» Changing the siren time
Enter + 41 + TS + Enter
TS = siren time from 01 to 99.
Note: factory default
5 minutes
, and if placed 00 on the command will be
beeped error.
» Register range RF amplier (REP 8000 repeater)
Enter + 622 + NA + Enter + Activate the amplier
by pressing the synchronisation
key