143
NA = amplier number from 01 to 04.
» Delete Range RF Amplier (REP 8000 Repeater)
Enter + 722 + NA + Enter
NA = number of amplier from 01 to 04.
» Reset wireless devices
» Delete all registered wireless devices
Enter + 7 + Disable + Enter
Note: all wireless devices in the alarm center, including the keyboard itself, will
be unregistered.
Changing RF Channel
Enter + 630 + RF + Enter
RF = channels from 08 to 11
Attention: When changing the channel of the alarm center, all devices registered
there (except remote control) must have the synchronization key pressed to direct
the device to the new channel, otherwise, they will not communicate with the
alarm center.
Remote update
» To download/checking a new version
Enter + 9922 + Enter
If there is a version to download, the
Download Wait
information will be
displayed and it will start, which will take about 3 to 5 minutes (variable
according to the connection used). If the alarm center does not have a version
for download will be shown
Alarm center is already updated. If you have any
problems on the network or Internet where the alarm center is connected, the
message will be displayed: Download failure.
» Install download version
Enter + 9933 + Enter
The new version that was downloaded will be installed and will not be lost
records and programming of the alarm center. To check the software version of
the alarm center, access
Menu
and with the arrow keys click on
Version of the
alarm center
to be displayed.