150
» Insert password of the network to be connected
Enter + 851 + Enter + Insert network password + Enter
» Enable/disable Wi-Fi
Note:
the alarm center connects only with 2.4GHz routers.
Enter + 852 + Enter + TP + Enter
TP = type of conguration.
Selection Type of conguration
0 Wi-Fi Disabled
1 Wi-Fi enabled / in case of AC failure, operates on battery
2 Wi-Fi enabled / only with active AC network
Settings for monitoring and SMS
» Schedule monitoring account
Enter + 15 + PP + Enter
, where PP = partition from 01 to 16
After the command, enter the 4-digit monitoring account number and press the
Enter
key to conrm.
» Program phone number for monitoring company
Enter + 10 + M + phone number of monitoring company + Enter
, where M =
memory for phone from 1 to 8
» Delete Phone
Enter + 10 + M + Disable + Enter
M = memory for phone from 1 to 8
» Phone Test
Enter + 11 + M + Enter
M = memory for phone from 1 to 8
» End Phone Test
Enter + 11 + Enter
» Event reporting mode
Enter + 17 + A + B + C + Enter
A = indicates in which mode the alarm center will operate from 0 to 7, where 0:
disabled, 1: regular phone, 2: not applicable, 3: dual phone, 4: regular IP, 5: not
applicable, 6: dual IP, 7: dual Mix.

Other manuals for Intelbras AMT 8000