151
B = indicates the protocol that will be used when phone 01 is dialed, being 0 =
Contact-ID and 1 = Programmable Contact-ID.
C = indicates the protocol that will be used when phone 01 is dialed, being 0 =
Contact-ID and 1 = Programmable Contact-ID.
Note: the
programmable Contact-ID
protocol can only be edited by the download/
upload software (
AMT 8000 programmer
).
» Program number of attempts to report an event
Enter + 13 + T + Enter
, where T = number of attempts from 1 to 9
» Program DTMF signal level
If the factory default DTMF level stored in the alarm center memory does not work,
type the following command and test all the options from 0 to 6 to see which one
gives the best result.
Enter + 18 + N + Enter
N = number of attempts from 0 to 6.
» Pending Event Reset
Enter + 16 + Enter
» Forced Service
Enter + 14 + Enter
» Ringtones to answer
Enter + 12 + T + Enter
T = number of rings to answer until the alarm center answers from 0 to 20.
» Program communication priority
Enter + 19 + P + Enter
P = communication priority from 0 to 3, where 0 = Ethernet, 1 = GPRS, 2 =
Ethernet/GPRS, 3 = GPRS/Ethernet.
» Program target IP
Enter + 801 + I + Enter
, where I = destination IP 1 or 2
After the command, enter the IP number of the monitoring company you hired
(example: 192.168.001.100) and press the
Enter
key to conrm.
» Program IP network communication port
Enter + 802 + P + Enter
P = port that will be used for the alarm center to connect, being 1 = port 1 and 2
= port 2.