155
Contact-ID Codes
For the following commands that congure the Contact-ID code, the communication
protocol must be set to Programmable Contact-ID (see
Event Reporting Mode
),
otherwise events will be sent with the standard Contact-ID.
» Set up Contact-ID code for zone opening type events
Enter
+ 901 + ZZ +
Enter
ZZ = zone from 01 to 64
After entering the command, enter the event value in hexadecimal format from
000 to FFF (accepts numbers from 0 to 9 and the letters B, C, D, E and F) and press
the
Enter
key to conrm. Factory default
130.
» Set Contact-ID code for zone restore type events
Enter + 911 + ZZ + Enter
ZZ = zone from 01 to 64
After entering the command, enter the event value in hexadecimal format from
000 to FFF (accepts numbers from 0 to 9 and the letters B, C, D, E and F) and press
the
Enter
key to conrm. Factory default
130.
» Set up Contact-ID code for tamper-open type events
Enter + 902 + ZZ + Enter
ZZ = zone from 01 to 64
After entering the command, enter the event value in hexadecimal format from
000 to FFF (accepts numbers from 0 to 9 and the letters B, C, D, E and F) and
press the
Enter
key to conrm. Factory default
145
for expansion devices and
383
for sensors.
» Setup Contact-ID code for tamper-restore type events
Enter + 912 + ZZ + Enter
ZZ = zone from 01 to 64
After entering the command, enter the event value in hexadecimal format from
000 to FFF (accepts numbers from 0 to 9 and the letters B, C, D, E and F) and
press the
Enter
key to conrm. Factory default
145
for expansion devices and
383
for sensors.
» Setup Contact-ID Code for User Deactivation Events
Enter + 903 + NU + Enter
NU = user number from 01 to 97