63
After entering the command, dene which partition the XSS 8000 siren will
belong to, with the address 00 as common (the siren will be triggered if an event
is generated on any of the partitions) or from 01 to 16 (the siren will be triggered
only if the partition to which it was dened, generates any event) according to
the desired partition and press
Enter
key to conrm. If you only want to view the
setting, press the
Exit
key and no programming will be changed.
Note: a siren can only be registered on a single partition or become common to all
partitions, and if the command is redone, only the last command will be valid.
Enable siren beep on system activation/deactivation
Activates/deactivates the beep emitted by the siren on activation/deactivation of
the alarm center. On activation, the siren will emit 1 beep and on deactivation, the
siren will emit 2 beeps. If any trouble is detected and the
Indication of troubles by
siren
function is enabled, the siren will emit 1 long beep on activation and 2 long
beeps on deactivation.
To program this function, type:
510
+
Enter
+
Enter
Use key
3
on the keyboard to enable the siren beep on activation/deactivation of
the system, so that the number 3 remains selected to enable and deselected to
disable the siren beep and then conrm with the
Enter
key. If you only want to view
the setting, press the
Back/Exit
key that no programming will be changed.
Note: » For partitioned or non-partitioned systems, only one siren will be responsible
for the activation/deactivation beep and follow the following behavior:
»
If the unit is not partitioned, only the siren registered at the lowest value
address will beep for activation and deactivation. If there are more sirens
registered at the unit and the siren of address 01 is removed from the
system, the beeper will be emitted by siren 02 and so on.
»
The next siren will beep only if the previous siren is deleted or after the unit
detects supervision failure.
»
If the unit is partitioned, when the general activation/deactivation is
performed or in more than one partition, the beep will be given in the
common siren, if it has one, or at the siren registered at the lowest address
(01).
»
If the system is partitioned and only one partition with its own siren is
activated, only one partition will be beep when the system is activated/
deactivated.