64
»
In case of partitioned system and with siren without partition dened for
it, beeping will take place on the common siren, if the system does not
have common siren, beeping will not have activation/deactivation for this
partition and neither will beeping of the other sirens for this partition in
case of triggering.
Enabling the siren beep in the activation/deactivation on a specic
partition
Select to which partitions the siren beep will be emitted in the activation/deactivation
of center when the same is partitioned by customizing the registered siren for each
partition. On activation, the siren will emit 1 beep and on deactivation, the siren
will emit 2 beeps. If any trouble is detected and the
Indication of troubles by siren
function is enabled, the siren will emit 1 long beep on activation and 2 long beeps
on deactivation.
To program this function, type:
+
Group of partitions224
+
Enter
0 or 1
+
Enter
After entering the command, using the XAT 8000 keyboard, mark which partitions
will have the siren beep active, using the numbers on the keyboard to leave a mark
on the partition. Select 0 for partition group 1 to 10 and 1 for partition 11 to 16.
After changing the congured value, press the
Enter
key. If you only want to view
the setting, press the
Back/Exit
key and no programming will be changed.
Siren Time
Siren time leaves the factory programmed for 5 minutes. This is the time that the
siren will be turned on/beeping after a violation/intrusion in any active partition/
zone occurs and can be changed to a time between 01 to 99 minutes.
To program this function, type:
+
4
+
Enter
01 to 99
minutes
+
Enter1 Siren Time