138 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
1.2.10.2 Battery (V)
Battery voltage:
12.8V
The screen shows the battery voltage.
1.2.11 Check card
Badge card
Keypad 1
Use the menu to read data from a user card.
Badge card on the keypad indicated on the screen the same way as it is done
when user card programming (see “3.1.n.3.1 Assign card” on page 163).
Note: The keypad for user card programming is defined in “8.8.5 Card learn-in”
on page 255.
If the card is programmed in the system, its holder user information is displayed:
User 05
J.Smith
Otherwise, if the card is unknown, its type and data is displayed in the same
format as in the event log.
CARD/TAG
98832665774
Badge another card, or press X to exit the menu.
1.2.12 Demo mode
1-8 Demo mode
>1234....<
Enable the Advisor Advanced demo mode.
Select areas where demo mode will be active.
In this mode the system operates with following limitations:
• All keypads assigned to selected areas display the following message:
DEMO MODE
Enabled
• Only access and entry/exit zones are operational.
• No mandatory events are reported to a central station and recorded in the
event log. The demo mode switching is not reported either.
See also “1.1 Display logs” on page 120.
• Engineer reset is disabled.
• Walk test is disabled.
• Internal and external siren outputs are disabled.