Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 249
This is a setting for panel only. For expanders, see “2.2.2.n.4.5 EOL” on page
152.
8.6.3 Siren tamper EOL
The Siren tamper end of line resistor menu allows you to define an end-of-line
resistor value for the siren. The available values are the same as in “8.6.2 EOL”
on page 248.
8.6.4 Swinger shunt
The Swinger shunt value defines the number of alarms from a zone until it is
shunted. The default value is 2, the maximum number is 4.
This zone must have the “4.1.n.6.6 Swinger shunt” option enabled (see
page 174).
8.6.5 Report restore
If the Report restore option is set to On ACK, the restore event is reported to the
central station when a user acknowledges an alarm.
If the option is set to On input close, the restore event is reported when the zone
returns to the normal state.
8.7 Panel and AB options
The Panel and AB options menu allows you to change particular system values.
See also “Initial start-up” on page 114.
If particular settings are changed in this menu, you are prompted to confirm those
changes while trying to leave this menu. See “Confirmation of changes” on
page 111.
8.7.1 Panel name
The Panel name menu lets you change the panel name.