IFS MCR200-1T/1CX User Manual                                                                                  9 
Installation  
Installing the MCR200-1T/1CX  
The MCR200-1T/1CX does not require any software 
configuration. Users can immediately use any feature of this 
product simply by attaching the cables and power plug. Based 
on the quality of the coaxial cable, the maximum distance of 
one connection is 3.0 km (9842 ft.) with 50 ohm coaxial cable. 
Changes in the cable quality would affect the maximum 
distance of a connection. 
MCR200-1T/1CX LAN to LAN connection 
Two sets of the MCR200-1T/1CX should be used to link two 
local Area networks that are located at different locations. 
Through a normal coaxial cable, the devices can be set up as 
a 100/65Mbps asymmetric backbone, but one MCR200-
1T/1CX must be selected as a Master (CO mode) and the 
other one as a Slave (CPE mode). 
 
Figure 3: MCR200-1T/1CX LAN to LAN connection