14 IFS MCR200-1T/1CX User Manual
Troubleshooting
SYMPTOM:
VDSL LNK LED does not light after the cable is connected to
the VDSL port.
CHECKPOINT:
Verify that the length of the cable connected between two
MCR200-1T/1CX units are not more than 3 km. Please
also try to adjust the DIP switch of MCR200-1T/1CX to
another SNR mode.
Please note you must use one MCR200-1T/1CX with CO
mode and the other MCR200-1T/1CX with CPE mode,
when connecting them together.
SYMPTOM:
TP LED does not light after a cable is connected to the port.
CHECKPOINT:
Verify that you are using either Cat.5, 5e, or 6 cables with
an RJ-45 connector to connect to the port.
If your device (i.e. LAN card) supports Auto-Negotiation, try
to set it to a fixed speed manually.
Make sure that both converter and the connected devices
are turned on.
Make sure that all cables are properly plugged in to the
correct ports.
Make sure that the cable is not bad.
Make sure that the power adapters are functional for each
device.